Oscillometric blood pressure: a review for clinicians

被引:165
作者
Alpert, Bruce S. [1 ]
Quinn, David [2 ]
Gallick, David [3 ]
机构
[1] Univ Tennessee, Hlth Sci Ctr, Dept Pediat, Div Cardiol, Memphis, TN USA
[2] Welch Allyn, Skaneateles Falls, NY USA
[3] Sun Tech, Morrisville, NC USA
关键词
Diastolic blood pressure; mean blood pressure; oscillometry; oscillometric blood pressure measurement; systolic blood pressure;
D O I
10.1016/j.jash.2014.08.014
中图分类号
R6 [外科学];
学科分类号
100210 [外科学];
摘要
Oscillometric devices for the non invasive estimation of blood pressure (BP) have become the "clinical standard" because of training requirements for determination of BP by auscultation, cost, and the phasing-out/banning of mercury in many states and countries. Analysis of recent publications reveals a lack of understanding of the "meaning" of oscillometric blood pressure (OBP) measurements by authors, journal editors, and clinicians. We were invited to submit a review of OBP methodology written for clinicians. We hope that the material contained herein will clarify how clinicians should interpret OBP values for their patients. (C) 2014 American Society of Hypertension. All rights reserved.
引用
收藏
页码:930 / 938
页数:9
相关论文
共 16 条
[1]
[Anonymous], 2013, 80601230 ISOIEC
[2]
Association for the Advancement of Medical Instrumentation, 2012, TIR44 ASS ADV MED IN
[3]
Association for the Advancement of Medical Instrumentation, 2013, 106022013 ANSIAAMII
[4]
E-J Marey, 1876, PHYSL EXP TRAV LAB M
[5]
Comparison of Aneroid and Oscillometric Blood Pressure Measurements in Children [J].
Eliasdottir, Sigridur B. ;
Steinthorsdottir, Sandra D. ;
Indridason, Olafur S. ;
Palsson, Runolfur ;
Edvardsson, Vidar O. .
JOURNAL OF CLINICAL HYPERTENSION, 2013, 15 (11) :776-783
[6]
Geddes L., 1991, HDB BLOOD PRESSURE M
[7]
CHARACTERIZATION OF THE OSCILLOMETRIC METHOD FOR MEASURING INDIRECT BLOOD-PRESSURE [J].
GEDDES, LA ;
VOELZ, M ;
COMBS, C ;
REINER, D ;
BABBS, CF .
ANNALS OF BIOMEDICAL ENGINEERING, 1982, 10 (06) :271-280
[8]
ERROR IN INDIRECT BLOOD-PRESSURE MEASUREMENT WITH INCORRECT SIZE OF CUFF [J].
GEDDES, LA ;
WHISTLER, SJ .
AMERICAN HEART JOURNAL, 1978, 96 (01) :4-8
[9]
AN AUTOMATED OSCILLOMETRIC TECHNIQUE FOR ESTIMATING MEAN ARTERIAL-PRESSURE IN CRITICALLY ILL NEWBORNS [J].
KIMBLE, KJ ;
DARNALL, RA ;
YELDERMAN, M ;
ARIAGNO, RL ;
REAM, AK .
ANESTHESIOLOGY, 1981, 54 (05) :423-425
[10]
Comparison between oscillometric and intra-arterial blood pressure measurements in ill preterm and full-term neonates [J].
Lalan, Shwetal ;
Blowey, Douglas .
JOURNAL OF THE AMERICAN SOCIETY OF HYPERTENSION, 2014, 8 (01) :36-44