Quality and safety of platelet apheresis concentrates produced with a new leukocyte reduction system

被引:16
作者
Riggert, J [1 ]
Humpe, A [1 ]
Simson, G [1 ]
Köhler, M [1 ]
机构
[1] Univ Gottingen, Dept Transfus Med, D-37075 Gottingen, Germany
关键词
D O I
10.1046/j.1423-0410.1998.7430182.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: Contaminating white blood cells (WBC) in apheresis platelet concentrates (PC) can cause a variety of adverse effects after platelet transfusion. To obtain PCs with low WBC contamination, a new leukoreduction system (LRS) utilizing 'fluidized particle bed' technology has recently been introduced. Methods: We prospectively examined the effect of LRS apheresis on the donor, the quality of the resulting PCs (n=120), and the platelet increment in the corresponding recipients. Conventionally prepared apheresis PCs served as control group (n=27). Platelet glycoproteins were examined by flow cytometry. Results: In LRS apheresis, we observed no serious adverse effects on the donors, but the postdonation absolute lymphocyte counts were reduced from 1,787+/-505/mu l to 1,405+/-383/mu l (p<0.001). Comparable results were seen in non-LRS donors. The collection efficiency of the LRS procedures was 50.0+/-7.6%, resulting in a yield of 4.3+/-1.0x10(11) platelets/PC. In flow cytometry, platelet glycoproteins in LRS PCs were not elevated: mean fluorescence of CD62 (6+/-4) or CD63 (9+/-3) in comparison with non-LRS PCs (mean fluorescence of CD62: 7+/-4, CD63: 8+/-3). Median leukocyte contamination of the LRS PCs was 0.41x10(5) (range 0.07-8.5) WBCs/unit. In 43 recipients, the 24-hour corrected count increments after transfusion of LRS PCs (12,530+/-8,761) wore essentially the same as those of 20 recipients of non-LRS PCs (13,133+/-9,812; p=0.75). Conclusions: LRS apheresis appears to be a safe procedure, which produced effective PCs with few contaminating leukocytes. With new apheresis technology, filtration of PCs may become superfluous.
引用
收藏
页码:182 / 188
页数:7
相关论文
共 26 条
[1]   THE USE OF A CHEMILUMINESCENCE-LINKED UNIVERSAL BACTERIAL RIBOSOMAL-RNA GENE PROBE AND BLOOD-GAS ANALYSIS FOR THE RAPID DETECTION OF BACTERIAL-CONTAMINATION IN WHITE CELL-REDUCED AND NONREDUCED PLATELETS [J].
BRECHER, ME ;
BOOTHE, G ;
KERR, A .
TRANSFUSION, 1993, 33 (06) :450-457
[2]   Effect of blood donation on the establishment of normal ranges of lymphocyte subsets [J].
Bryant, JA ;
Wylie, BR ;
Yuan, FF ;
Ribeiro, A ;
Thomson, AR ;
Cooley, MA ;
Fletcher, A .
TRANSFUSION, 1996, 36 (06) :559-566
[3]   EFFECTS OF WHITE CELL-REDUCTION ON THE RESISTANCE OF BLOOD COMPONENTS TO BACTERIAL MULTIPLICATION [J].
BUCHHOLZ, DH ;
AUBUCHON, JP ;
SNYDER, EL ;
KANDLER, R ;
PISCITELLI, V ;
PICKARD, C ;
NAPYCHANK, P ;
EDBERG, S .
TRANSFUSION, 1994, 34 (10) :852-857
[4]   PLATELETPHERESIS - COMPARISON OF PLATELET YIELDS, PROCESSING TIME, AND WHITE CELL CONTENT WITH 2 APHERESIS SYSTEMS [J].
BURGSTALER, EA ;
PINEDA, AA ;
BRECHER, MA .
TRANSFUSION, 1993, 33 (05) :393-398
[5]   Practical guidelines for process validation and process control of white cell-reduced blood components: Report of the biomedical excellence for safer transfusion (BEST) working party of the international society of blood transfusion (ISBT) [J].
Dumont, LJ ;
Dzik, WH ;
Rebulla, P ;
Brandwein, H .
TRANSFUSION, 1996, 36 (01) :11-20
[6]   Evaluation of platelet function using the in vitro bleeding time and corrected count increment of transfused platelets [J].
Eriksson, L ;
Kristensen, J ;
Olsson, K ;
Bring, J ;
Hogman, CF .
VOX SANGUINIS, 1996, 70 (02) :69-75
[7]   Characterization of reactions after transfusion of cellular blood components that are white cell reduced before storage [J].
Federowicz, I ;
Barrett, BB ;
Andersen, JW ;
Urashima, M ;
Popovsky, MA ;
Anderson, KC .
TRANSFUSION, 1996, 36 (01) :21-28
[8]   THE FEBRILE PLATELET TRANSFUSION REACTION - A CYTOKINE SHOWER [J].
FERRARA, JLM .
TRANSFUSION, 1995, 35 (02) :89-90
[9]  
FISCHER M, 1985, VOX SANG, V49, P331
[10]   WHITE CELL-REDUCTION IN PLATELET CONCENTRATES AND PACKED RED-CELLS BY FILTRATION - A MULTICENTER CLINICAL-TRIAL [J].
KAO, KJ ;
MICKEL, M ;
BRAINE, HG ;
DAVIS, K ;
ENRIGHT, H ;
GERNSHEIMER, T ;
GILLESPIE, MJ ;
KICKLER, TS ;
LEE, EJ ;
MCCULLOUGH, JJ ;
MCFARLAND, JG ;
NEMO, GJ ;
NOYES, WD ;
SCHIFFER, CA ;
SELL, K ;
SLICHTER, SJ ;
WOODSON, RD .
TRANSFUSION, 1995, 35 (01) :13-19