Universal two-dimensional HPLC technique for the chemical analysis of complex surfactant mixtures

被引:56
作者
Haefliger, OP [1 ]
机构
[1] Firmenich Co, Corp R&D Div, CH-1211 Geneva 8, Switzerland
关键词
D O I
10.1021/ac020534d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two-dimensional HPLC was applied for the first time to the analysis of complex surfactant mixtures. In the first dimension, ion chromatographic-type separations were performed on a diol column eluted by an acetonitrile-water (0.1% brifluoroacetic acid) gradient. Using this new technique, cationic and amphoteric surfactants were not retained at all, nonionic surfactants exhibited a weak and essentially unspecific retention, and anionic surfactants were retained mainly according to their functional group. Rather than detecting the analytes immediately after this first separation, successive fractions were automatically and quantitatively transferred to parallel C2 (dimethyl) and C4 (butyl) reversed-phase columns using an innovative setup. The second dimension of the separation then took place, by which the analytes were separated according to their hydrophobicity. Surfactants from all four classes, cationic, amphoteric, nonionic, and anionic, were separated simultaneously in single 54-min two-dimensional HPLC runs. The suitability of the method for quantitative measurements was demonstrated.
引用
收藏
页码:371 / 378
页数:8
相关论文
共 25 条
[1]   Analysis of alkyl sulfonates and carboxylates using high performance ion chromatography [J].
Bevers, HAJM ;
Hulst, R .
CHROMATOGRAPHIA, 2000, 52 (3-4) :162-164
[2]   AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PROTEINS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (02) :161-167
[3]   THE EFFECTS OF ZWITTERIONIC SURFACTANT SYSTEMS UPON AROMATIC NUCLEOPHILIC-SUBSTITUTION [J].
CIPICIANI, A ;
PRIMIERI, S .
JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 1990, (08) :1365-1367
[4]   2-DIMENSIONAL COLUMN LIQUID-CHROMATOGRAPHIC TECHNIQUE FOR RESOLUTION OF COMPLEX-MIXTURES [J].
ERNI, F ;
FREI, RW .
JOURNAL OF CHROMATOGRAPHY, 1978, 149 (FEB) :561-569
[5]   SEPARATION OF NANOLITER SAMPLES OF BIOLOGICAL AMINES BY A COMPREHENSIVE 2-DIMENSIONAL MICROCOLUMN LIQUID-CHROMATOGRAPHY SYSTEM [J].
HOLLAND, HA ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1995, 67 (18) :3275-3283
[6]  
Holland LA, 2000, J MICROCOLUMN SEP, V12, P371, DOI 10.1002/1520-667X(2000)12:6<371::AID-MCS6>3.0.CO
[7]  
2-N
[8]   Coupling of a microbore column with a column packed with non-porous particles for fast comprehensive two-dimensional high-performance liquid chromatography [J].
Köhne, AP ;
Welsch, T .
JOURNAL OF CHROMATOGRAPHY A, 1999, 845 (1-2) :463-469
[9]  
MATSUZAKI M, 1993, J SOC COSMET CHEM JP, V27, P494
[10]  
Meade E. M., 1949, U. S. Patent, Patent No. [2,464,094, 2464094]