A quantitative diffraction-based sandwich immunoassay

被引:57
作者
Goh, JB
Tam, PL
Loo, RW
Goh, MC
机构
[1] Univ Toronto, Dept Chem, Toronto, ON M5S 3H6, Canada
[2] Axela Biosensors Inc, Toronto, ON M5H 3W4, Canada
关键词
biosensor; diffraction; immunoassay; microcontact printing; sandwich assay;
D O I
10.1016/S0003-2697(02)00634-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
It is shown that diffraction-based sensing can be enhanced for diagnostic purposes through the use of a secondary label. The limit of detection for anti-rabbit IgG was reduced more than 40-fold by using a gold-conjugated secondary antibody. The response to secondary antibody binding was linear for concentrations from 25 to 500 ng/ml of anti-rabbit IgG, suggesting that quantitative determinations can be readily done. Moreover, the binding of the secondary antibody was observed as soon as 1 min after its introduction to the surface-bound primary complex. (C) 2003 Elsevier Science (USA). All rights reserved.
引用
收藏
页码:262 / 266
页数:5
相关论文
共 12 条
[1]   Large-scale resonance amplification of optical sensing of volatile compounds with chemoresponsive visible-region diffraction gratings [J].
Bailey, RC ;
Hupp, JT .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2002, 124 (23) :6767-6774
[2]   Printing patterns of proteins [J].
Bernard, A ;
Delamarche, E ;
Schmid, H ;
Michel, B ;
Bosshard, HR ;
Biebuyck, H .
LANGMUIR, 1998, 14 (09) :2225-2229
[3]   Diffraction-based assay for detecting multiple analytes [J].
Goh, JB ;
Loo, RW ;
McAloney, RA ;
Goh, MC .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (01) :54-56
[4]   Immunosensors - principles and applications to clinical chemistry [J].
Luppa, PB ;
Sokoll, LJ ;
Chan, DW .
CLINICA CHIMICA ACTA, 2001, 314 (1-2) :1-26
[5]  
Mines GA, 2002, ANGEW CHEM INT EDIT, V41, P154, DOI 10.1002/1521-3773(20020104)41:1<154::AID-ANIE154>3.0.CO
[6]  
2-F
[7]   Immobilization of antibodies in micropatterns for cell detection by optical diffraction [J].
Morhard, F ;
Pipper, J ;
Dahint, R ;
Grunze, M .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 70 (1-3) :232-242
[8]   Surface plasmon resonance-based immunoassays [J].
Mullett, WM ;
Lai, EPC ;
Yeung, JM .
METHODS, 2000, 22 (01) :77-91
[9]   Diffractive optical chemical sensor based on light absorption [J].
Nakajima, F ;
Hirakawa, Y ;
Kaneta, T ;
Imasaka, T .
ANALYTICAL CHEMISTRY, 1999, 71 (13) :2262-2265
[10]   Diffraction-based cell detection using a microcontact printed antibody grating [J].
St John, PM ;
Davis, R ;
Cady, N ;
Czajka, J ;
Batt, CA ;
Craighead, HG .
ANALYTICAL CHEMISTRY, 1998, 70 (06) :1108-1111