Rainwater harvesting, quality assessment and utilization in Kefalonia Island, Greece

被引:212
作者
Sazakli, E. [1 ]
Alexopoulos, A. [1 ]
Leotsinidis, M. [1 ]
机构
[1] Univ Patras, Publ Hlth Lab, Sch Med, Rion 26500, Greece
关键词
rainwater harvesting; microbial indicators; chemicals;
D O I
10.1016/j.watres.2007.01.037
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The quality of harvested rainwater which is used for domestic and drinking purposes in the northern area of Kefalonia Island in SW Greece and the factors affecting it were assessed through 3-year surveillance. In 12 seasonal samplings, 156 rainwater and 144 ground- or mixed water samples were collected from ferroconcrete storage tanks (300-1000 m(3) capacity), which are adjacent to cement-paved catchment areas (600-3000 m(2)). Common anions and major cations as well as the metals Fe, Mn, Cd, Pb, Cu, Cr, Ni and Zn were tested. The presence of three major groups of organic compounds, polycyclic aromatic hydrocarbons (PAHs), organochloride pesticides (OCPs) and volatile organic compounds (VOCs), was screened by common analytical techniques. All of the rainwater samples were within the guidelines for chemical parameters established by the 98/93/EU directive. As far as microbiological quality is concerned, total coliforms, Escherichia coli and enterococci were detected in 80.3%, 40.9% and 28.8% of the rainwater samples, respectively, although they were found in low concentrations. Chemical and microbiological parameters showed seasonal fluctuations. Principal component analysis revealed that microbiological parameters were affected mainly by the cleanness level of catchment areas, while chemical parameters were influenced by the sea proximity and human activities. Disinfection should be applied into the tanker trucks which distribute the water to the consumers and not into the big storage tanks in order to avoid by-products formation. Due to the lack of fluoride in rainwater samples, the consumers must become aware of the fact that the supplementation of this element is needed. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2039 / 2047
页数:9
相关论文
共 25 条
[1]  
[Anonymous], 1998, Off J Eur Union L, V330, P32
[2]  
APHA AWWA WEF, 1995, STAND METH EX WAT WA
[3]   Roofing as a source of nonpoint water pollution [J].
Chang, MT ;
McBroom, MW ;
Beasley, RS .
JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2004, 73 (04) :307-315
[4]   Microbial partitioning to settleable particles in stormwater [J].
Characklis, GW ;
Dilts, MJ ;
Simmons, OD ;
Likirdopulos, CA ;
Krometis, LAH ;
Sobsey, MD .
WATER RESEARCH, 2005, 39 (09) :1773-1782
[5]   RAINWATER CATCHMENT WATER-QUALITY IN MICRONESIA [J].
DILLAHA, TA ;
ZOLAN, WJ .
WATER RESEARCH, 1985, 19 (06) :741-746
[6]  
EPA, 2003, 5030C EPA
[7]  
*EPA, 1998, 8081B EPA
[8]  
EPA Environmental Protection Agency, 2003, 8015D EPA
[9]   Wind, rain and bacteria: The effect of weather on the microbial composition of roof-harvested rainwater [J].
Evans, CA ;
Coombes, PJ ;
Dunstan, RH .
WATER RESEARCH, 2006, 40 (01) :37-44
[10]  
Evison L, 2001, J AM WATER WORKS ASS, V93, P85