Coronary optical frequency domain imaging (OFDI) for in vivo evaluation of stent healing: comparison with light and electron microscopy

被引:93
作者
Templin, Christian [1 ]
Meyer, Martin [1 ]
Mueller, Maja Franziska [1 ]
Djonov, Valentin [2 ]
Hlushchuk, Ruslan [2 ]
Dimova, Ivanka [2 ]
Flueckiger, Stefanie [2 ]
Kronen, Peter [3 ,4 ]
Sidler, Michele [3 ,4 ]
Klein, Karina [4 ,5 ]
Nicholls, Flora [6 ]
Ghadri, Jelena-Rima [1 ]
Weber, Klaus [7 ]
Paunovic, Dragica [8 ]
Corti, Roberto [1 ]
Hoerstrup, Simon P. [9 ]
Luescher, Thomas F. [1 ]
Landmesser, Ulf [1 ]
机构
[1] Univ Zurich Hosp, Dept Cardiol, Ctr Cardiovasc, CH-8091 Zurich, Switzerland
[2] Univ Fribourg, Dept Med Gross Anat & Vasc Biol, CH-1700 Fribourg, Switzerland
[3] Vet Anaesthesia Serv Int, CH-8400 Winterthur, Switzerland
[4] Univ Zurich, CABMM, Vetsuisse Fac, CH-8057 Zurich, Switzerland
[5] Univ Zurich, Musculoskeletal Res Unit MSRU, Vetsuisse Fac, CH-8057 Zurich, Switzerland
[6] Univ Zurich Hosp, Inst Lab Anim Sci, CH-8091 Zurich, Switzerland
[7] Harlan Labs Ltd, CH-4452 Itingen, Switzerland
[8] Terumo Europe NV, European Med & Clin Div, Leuven, Belgium
[9] Univ Zurich Hosp, Cardiovasc Surg Clin, Dept Surg Res, CH-8091 Zurich, Switzerland
基金
新加坡国家研究基金会;
关键词
Optical frequency domain imaging; Stent strut coverage; Histological validation; DRUG-ELUTING STENTS; LARGE 2-INSTITUTIONAL COHORT; ROUTINE CLINICAL-PRACTICE; COHERENCE TOMOGRAPHY; MYOCARDIAL-INFARCTION; THROMBOSIS; SIROLIMUS; IMPLANTATION; COVERAGE; ENDOTHELIALIZATION;
D O I
10.1093/eurheartj/ehq168
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Coronary late stent thrombosis, a rare but devastating complication, remains an important concern in particular with the increasing use of drug-eluting stents. Notably, pathological studies have indicated that the proportion of uncovered coronary stent struts represents the best morphometric predictor of late stent thrombosis. Intracoronary optical frequency domain imaging (OFDI), a novel second-generation optical coherence tomography (OCT)derived imaging method, may allow rapid imaging for the detection of coronary stent strut coverage with a markedly higher precision when compared with intravascular ultrasound, due to a microscopic resolution (axial similar to 10-20 mu m), and at a substantially increased speed of image acquisition when compared with first-generation time-domain OCT. However, a histological validation of coronary OFDI for the evaluation of stent strut coverage in vivo is urgently needed. Hence, the present study was designed to evaluate the capacity of coronary OFDI by electron (SEM) and light microscopy (LM) analysis to detect and evaluate stent strut coverage in a porcine model. Methods and results Twenty stents were implanted into 10 pigs and coronary OFDI was performed after 1, 3, 10, 14, and 28 days. Neointimal thickness as detected by OFDI correlated closely with neointimal thickness as measured by LM (r = 0.90, P < 0.01). The comparison of stent strut coverage as detected by OFDI and SEM analysis revealed an excellent agreement (r = 0.96, P < 0.01). In particular, stents completely covered by OFDI analysis were also completely covered by SEM analysis. All incompletely covered stents by OFDI were also incompletely covered by SEM. Analyses of fibrin-covered stent struts suggested that these may rarely be detected as uncovered stent struts by OFDI. Importantly, optical density measurements revealed a significant difference between fibrin-and neointima-covered coronary stent struts [0.395 (0.35-0.43) vs. 0.53 (0.47-0.57); P < 0.001], suggesting that differences in optical density provide information on the type of stent strut coverage. The sensitivity and specificity for detection of fibrin vs. neointimal coverage was evaluated using receiver-operating characteristic analysis. Conclusion The present study demonstrates that OFDI is a highly promising tool for accurate evaluation of coronary stent strut coverage, as supported by a high agreement between OFDI and light and electron microscopic analysis. Furthermore, our data indicate that optical density measurements can provide additional information with respect to the type of stent strut coverage, i.e. fibrin vs. neointimal coverage. Therefore, coronary OFDI analysis will provide important information on the biocompatibility of coronary stents.
引用
收藏
页码:1792 / 1801
页数:10
相关论文
共 27 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   Time course of stent endothelialization after intravascular radiation therapy in rabbit iliac arteries [J].
Cheneau, E ;
John, MC ;
Fournadjiev, J ;
Chan, RC ;
Kim, HS ;
Leborgne, L ;
Pakala, R ;
Yazdi, H ;
Ajani, AE ;
Virmani, R ;
Waksman, R .
CIRCULATION, 2003, 107 (16) :2153-2158
[3]   Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice:: data from a large two-institutional cohort study [J].
Daemen, Joost ;
Wenaweser, Peter ;
Tsuchida, Keiichi ;
Abrecht, Linda ;
Sophia, Vaina ;
Morger, Cyrill ;
Kukreja, Neville ;
Jueni, Peter ;
Sianos, Georgios ;
Hellige, Gerrit ;
van Domburg, Ron T. ;
Hess, Otto M. ;
Boersma, Eric ;
Meier, Bernhard ;
Windecker, Stephan ;
Serruys, Patrick W. .
LANCET, 2007, 369 (9562) :667-678
[4]  
DONATH K, 1993, PREPARATION HISTOLOG
[5]   Vascular responses to drug eluting stents - Importance of delayed healing [J].
Finn, Aloke V. ;
Nakazawa, Gaku ;
Joner, Michael ;
Kolodgie, Frank D. ;
Mont, Erik K. ;
Gold, Herman K. ;
Virmani, Renu .
ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2007, 27 (07) :1500-1510
[6]   Pathological correlates of late drug-eluting stent thrombosis - Strut coverage as a marker of endothelialization [J].
Finn, Aloke V. ;
Joner, Michael ;
Nakazawa, Gaku ;
Kolodgie, Frank ;
Newell, John ;
John, Mike C. ;
Gold, Herman K. ;
Virmani, Renu .
CIRCULATION, 2007, 115 (18) :2435-2441
[7]   Incomplete Stent Apposition and Delayed Tissue Coverage Are More Frequent in Drug-Eluting Stents Implanted During Primary Percutaneous Coronary Intervention for ST-Segment Elevation Myocardial Infarction Than in Drug-Eluting Stents Implanted for Stable/Unstable Angina Insights From Optical Coherence Tomography [J].
Gonzalo, Nieves ;
Barlis, Peter ;
Serruys, Patrick W. ;
Garcia-Garcia, Hector M. ;
Onuma, Yoshinobu ;
Ligthart, Jurgen ;
Regar, Evelyn .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (05) :445-452
[8]   Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents [J].
Iakovou, I ;
Schmidt, T ;
Bonizzoni, E ;
Ge, L ;
Sangiorgi, GM ;
Stankovic, G ;
Airoldi, F ;
Chieffo, A ;
Montorfano, M ;
Carlino, M ;
Michev, I ;
Corvaja, N ;
Briguori, C ;
Gerckens, U ;
Grube, E ;
Colombo, A .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (17) :2126-2130
[9]   Pathology of drug-eluting stents in humans - Delayed healing and late thrombotic risk [J].
Joner, Michael ;
Finn, Aloke V. ;
Farb, Andrew ;
Mont, Erik K. ;
Kolodgie, Frank D. ;
Ladich, Elena ;
Kutys, Robert ;
Skorija, Kristi ;
Gold, Herman K. ;
Virmani, Renu .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (01) :193-202
[10]   Safety and Efficacy of Drug-Eluting and Bare Metal Stents Comprehensive Meta-Analysis of Randomized Trials and Observational Studies [J].
Kirtane, Ajay J. ;
Gupta, Anuj ;
Iyengar, Srinivas ;
Moses, Jeffrey W. ;
Leon, Martin B. ;
Applegate, Robert ;
Brodie, Bruce ;
Hannan, Edward ;
Harjai, Kishore ;
Jensen, Lisette Okkels ;
Park, Seung-Jung ;
Perry, Raphael ;
Racz, Michael ;
Saia, Francesco ;
Tu, Jack V. ;
Waksman, Ron ;
Lansky, Alexandra J. ;
Mehran, Roxana ;
Stone, Gregg W. .
CIRCULATION, 2009, 119 (25) :3198-U78