The BNM watt balance project

被引:93
作者
Genevès, G [1 ]
Gournay, P
Gosset, A
Lecollinet, M
Villar, F
Pinot, P
Juncar, P
Clairon, A
Landragin, A
Holleville, D
Dos Santos, FP
David, J
Besbes, M
Alves, F
Chassagne, L
Topçu, S
机构
[1] Bur Natl Metrol, Lab Natl Essais, Ctr Metrol Elect, BNM LNE CME, F-78197 Trappes, France
[2] Bur Natl Metrol, Lab Natl Essais, Ctr Metrol & Instrumentat, BNM LNE CMI, F-75015 Paris, France
[3] Bur Natl Metrol, Inst Natl Metrol, Conservatoire Natl Arts & Metiers, BNM INM CNAM, F-75003 Paris, France
[4] Bur Natl Metrol, Syst Reference Temps Espace BNM SYRTE, Observ Paris, F-75104 Paris, France
[5] Ecole Natl Super Arts & Metiers ENSAM, F-59046 Lille, France
[6] Ecole Super Elect, Lab Genie Elect Paris, F-91192 Gif Sur Yvette, France
[7] Ecole Normal Super Cachan, SATIE, UMR 8029, CNRS, F-94235 Cachan, France
[8] Univ Versailles St Quentin Yvelines, LIRIS, F-78035 Versailles, France
关键词
kilogram; Planck's constant; watt balance;
D O I
10.1109/TIM.2005.843576
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new watt balance project is now in progress at the Bureau National de Metrologie (BNM), Paris, France. In this paper, the general configuration and the main parts of the experimental setup currently in development are presented. The aim is to contribute to the international effort in monitoring the kilogram toward a new definition of the mass unit with a relative accuracy of 10(-8) or better.
引用
收藏
页码:850 / 853
页数:4
相关论文
共 13 条
[1]   Determination of the Avogadro constant via the silicon route [J].
Becker, P ;
Bettin, H ;
Danzebrink, HU ;
Gläser, M ;
Kuetgens, U ;
Nicolaus, A ;
Schiel, D ;
De Bièvre, P ;
Valkiers, S ;
Taylor, P .
METROLOGIA, 2003, 40 (05) :271-287
[2]   A proposal for a new moving-coil experiment [J].
Beer, W ;
Jeanneret, B ;
Jeckelmann, B ;
Richard, P ;
Courteville, A ;
Salvadé, Y ;
Dändliker, R .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1999, 48 (02) :192-195
[3]  
*BIPM, 1999, DEF KIL
[4]  
CHEINET P, 2004, DIG C PRECISION ELEC, P60
[5]   Tracing Planck's constant to the kilogram by electromechanical methods [J].
Eichenberger, A ;
Jeckelmann, B ;
Richard, P .
METROLOGIA, 2003, 40 (06) :356-365
[6]   THE 3RD PERIODIC VERIFICATION OF NATIONAL PROTOTYPES OF THE KILOGRAM (1988-1992) [J].
GIRARD, G .
METROLOGIA, 1994, 31 (04) :317-336
[7]   Tracing the atomic mass unit to the kilogram by ion accumulation [J].
Gläser, M .
METROLOGIA, 2003, 40 (06) :376-386
[8]  
GOURNAY P, 2004, DIG C PREC EL MEAS C, P510
[9]  
Kibble B P, 1975, ATOMIC MASSES FUNDAM, V5, P545
[10]   THE BEAM BALANCE AS AN INSTRUMENT FOR VERY PRECISE WEIGHING [J].
QUINN, TJ .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1992, 3 (02) :141-159