A continuous electrical cell lysis device using a low dc voltage for a cell transport and rupture

被引:75
作者
Lee, Dong Woo
Cho, Young-Ho
机构
[1] Korea Adv Inst Sci & Technol, Digital Nanolocomot Ctr, Taejon 305701, South Korea
[2] Korea Adv Inst Sci & Technol, Dept Biosyst, Taejon 305701, South Korea
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2007年 / 124卷 / 01期
关键词
cell lysis; electroosmosis; electroosmotic pump; electric field modulation;
D O I
10.1016/j.snb.2006.11.054
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present a continuous and low voltage cell lysis device in which a width and length of a channel change to generate focused the high electric field strength for cell lysis and the low electric field strength for a transport of samples. The previous cell lysis devices acquire the high electric field strength for a cell lysis by applying an ac voltage to a micro-gap between electrodes and require additional pumps or valves for a sample transport. However, when we change the width and length of the channel between a pair of external electrodes attached to a dc voltage, we generate both the high electric field strength for a cell lysis and the low electric field strength for an electroosmotic flow. The present device therefore performs continuous cell lysis and a sample transport without needing either an additional flow source or an additional process fabricating the electrodes for the micro-gap. The experimental study features an orifice whose width and length is 20 times narrower and 175 times shorter than the width and length of a microchannel. With an operational voltage of 50 V, the present device generates high electric field strength of 1.2 kV/cm at the orifice to disrupt cells with 100% lysis rate of red blood cells and low electric field strength of 60 V/cm at the microchannel to generate an electroosmotic flow of 30 +/- 9 mu m/s. In conclusion, the present device is capable of continuous self-pumping cell lysis at a low voltage; thus, it is suitable for a sample pretreatment component of a micro total analysis system or lab-on-a-chip. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:84 / 89
页数:6
相关论文
共 13 条
[1]   Continuous spore disruption using radially focused, high-frequency ultrasound [J].
Chandler, DP ;
Brown, J ;
Bruckner-Lea, CJ ;
Olson, L ;
Posakony, GJ ;
Stults, JR ;
Valentine, NB ;
Bond, LJ .
ANALYTICAL CHEMISTRY, 2001, 73 (15) :3784-3789
[2]   On-chip cell lysis by local hydroxide generation [J].
Di Carlo, D ;
Ionescu-Zanetti, C ;
Zhang, Y ;
Hung, P ;
Lee, LP .
LAB ON A CHIP, 2005, 5 (02) :171-178
[3]   Integration of single cell injection, cell lysis, separation and detection of intracellular constituents on a microfluidic chip [J].
Gao, J ;
Yin, XF ;
Fang, ZL .
LAB ON A CHIP, 2004, 4 (01) :47-52
[4]  
Graham J. M., 1997, SUBCELLULAR FRACTION, V175
[5]   Microfabricated electroporation chip for single cell membrane permeabilization [J].
Huang, Y ;
Rubinsky, B .
SENSORS AND ACTUATORS A-PHYSICAL, 2001, 89 (03) :242-249
[6]   MEMS-based sample preparation for molecular diagnostics [J].
Huang, Y ;
Mather, EL ;
Bell, JL ;
Madou, M .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 372 (01) :49-65
[7]   Electric manipulation of bioparticles and macromolecules on microfabricated electrodes [J].
Huang, Y ;
Ewalt, KL ;
Tirado, M ;
Haigis, TR ;
Forster, A ;
Ackley, D ;
Heller, MJ ;
O'Connell, JP ;
Krihak, M .
ANALYTICAL CHEMISTRY, 2001, 73 (07) :1549-1559
[8]   A micro cell lysis device [J].
Lee, SW ;
Tai, YC .
SENSORS AND ACTUATORS A-PHYSICAL, 1999, 73 (1-2) :74-79
[9]   Transport, manipulation, and reaction of biological cells on-chip using electrokinetic effects [J].
Li, PCH ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1997, 69 (08) :1564-1568
[10]   Electroporation microchips for continuous gene transfection [J].
Lin, YC ;
Jen, CM ;
Huang, MY ;
Wu, CY ;
Lin, XZ .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 79 (2-3) :137-143