Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure

被引:845
作者
Michard, F
Boussat, S
Chemla, D
Anguel, N
Mercat, A
Lecarpentier, Y
Richard, C
Pinsky, MR
Teboul, JL
机构
[1] CHU Bicetre, Assistance Publ Hop Paris, Serv Reanimat Med, Le Kremlin Bicetre, France
[2] CHU Bicetre, Assistance Publ Hop Paris, Serv Physiol Cardioresp, Le Kremlin Bicetre, France
[3] Univ Paris 11, Paris, France
[4] Ecole Polytech, INSERM U451 LOA ENSTA, Palaiseau, France
[5] Univ Pittsburgh, Div Crit Care Med, Pittsburgh, PA USA
关键词
D O I
10.1164/ajrccm.162.1.9903035
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
In mechanically ventilated patients with acute circulatory failure related to sepsis, we investigated whether the respiratory changes in arterial pressure could be related to the effects of volume expansion (VE) on cardiac index (CI). Forty patients instrumented with indwelling systemic and pulmonary artery catheters were studied before and after VE. Maximal and minimal values of pulse pressure (Pp(max) and Pp(min)) and systolic pressure (Ps(max) and Ps(min)) were determined over one respiratory cycle. The respiratory changes in pulse pressure (Delta Pp) were calculated as the difference between Pp(max) and Pp(min) divided by the mean of the two values and were expressed as a percentage. The respiratory changes in systolic pressure (Delta Ps) were calculated using a similar formula. The VE-induced increase in CI was greater than or equal to 15% in 16 patients (responders) and < 15% in 24 patients (nonresponders). Before VE, Delta Pp (24 +/- 9 versus 7 +/- 3%, p < 0.001) and Delta Ps (15 +/- 5 versus 6 +/- 3%, p < 0.001) were higher in responders than in nonresponders. Receiver operating characteristic (ROC) curves analysis showed that Delta Pp was a more accurate indicator of fluid responsiveness than Delta Ps. Before VE, a Delta Pp value of 13% allowed discrimination between responders and nonresponders with a sensitivity of 94% and a specificity of 96%. VE-induced changes in CI closely correlated with Delta Pp before volume expansion (r(2) = 0.85, p < 0.001). VE decreased Delta Pp from 14 +/- 10 to 7 +/- 5% (p < 0.001) and VE-induced changes in Delta Pp correlated with VE-induced changes in CI (r(2) = 0.72, p < 0.001). it was concluded that in mechanically ventilated patients with acute circulatory failure related to sepsis, analysis of Delta Pp is a simple method for predicting and assessing the hemodynamic effects of VE, and that Delta Pp is a more reliable indicator of fluid responsiveness than Delta Ps.
引用
收藏
页码:134 / 138
页数:5
相关论文
共 24 条
[1]  
[Anonymous], 1991, TXB MED PHYSL
[2]   Septic shock [J].
Astiz, ME ;
Rackow, EC .
LANCET, 1998, 351 (9114) :1501-1505
[3]  
Berne RM, 1998, PHYSIOLOGY, P415
[4]   DEFINITIONS FOR SEPSIS AND ORGAN FAILURE AND GUIDELINES FOR THE USE OF INNOVATIVE THERAPIES IN SEPSIS [J].
BONE, RC ;
BALK, RA ;
CERRA, FB ;
DELLINGER, RP ;
FEIN, AM ;
KNAUS, WA ;
SCHEIN, RMH ;
SIBBALD, WJ .
CHEST, 1992, 101 (06) :1644-1655
[5]  
CORIAT P, 1994, ANESTH ANALG, V78, P46
[6]   A METHOD OF COMPARING THE AREAS UNDER RECEIVER OPERATING CHARACTERISTIC CURVES DERIVED FROM THE SAME CASES [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1983, 148 (03) :839-843
[7]   REEVALUATION OF HEMODYNAMIC CONSEQUENCES OF POSITIVE PRESSURE VENTILATION - EMPHASIS ON CYCLIC RIGHT VENTRICULAR AFTERLOADING BY MECHANICAL LUNG-INFLATION [J].
JARDIN, F ;
DELORME, G ;
HARDY, A ;
AUVERT, B ;
BEAUCHET, A ;
BOURDARIAS, JP .
ANESTHESIOLOGY, 1990, 72 (06) :966-970
[8]   CYCLIC CHANGES IN ARTERIAL PULSE DURING RESPIRATORY SUPPORT [J].
JARDIN, F ;
FARCOT, JC ;
GUERET, P ;
PROST, JF ;
OZIER, Y ;
BOURDARIAS, JP .
CIRCULATION, 1983, 68 (02) :266-274
[9]   RESPIRATORY VARIATIONS IN RIGHT ATRIAL PRESSURE PREDICT THE RESPONSE TO FLUID CHALLENGE [J].
MAGDER, S ;
GEORGIADIS, G ;
CHEONG, T .
JOURNAL OF CRITICAL CARE, 1992, 7 (02) :76-85
[10]   More respect for the CVP [J].
Magder, S .
INTENSIVE CARE MEDICINE, 1998, 24 (07) :651-653