Rotator cuff repair with bioabsorbable screws: An in vivo and ex vivo investigation

被引:48
作者
Cummins, CA
Strickland, S
Appleyard, RC
Szomor, ZL
Marshall, J
Murrell, GAC
机构
[1] Orthopaed Res Inst, Kogarah, NSW, Australia
[2] Hosp Special Surg, New York, NY 10021 USA
关键词
rotator cuff; bioabsorbable; anchors; biomechanical; load to failure; ovine infraspinatus model;
D O I
10.1053/jars.2003.50013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to evaluate in vivo the clinical outcomes of rotator cuff repairs with bioabsorbable screws compared with metal suture anchors, and to compare the ex vivo initial load to failure of rotator cuff repairs using 3 different bioabsorbable screws, suture anchors, and transosseous sutures. Type of Study: In vivo clinical outcomes investigation, and ex vivo biomechanical study. Methods: Three cohorts of patients with rotator cuff tears that measured less than 4 cm(2), were sequentially repaired with Mitek Rotator Cuff QuickAnchors (Mitek Surgical Products; Norwood, MA) (n = 9), Arthrex Headed Bio-Corkscrews (n = 9) (Arthrex, Naples, FL), and Mitek Rotator Cuff QuickAnchors (n = 9). Patients were systematically assessed with a specific shoulder questionnaire and 23 shoulder tests performed preoperatively and at 1 and 6 weeks, 3 and 6 months, and 1 year postoperatively. A correlative ex vivo biomechanical study was performed on 53 ovine shoulders to evaluate the initial failure load properties of bioabsorbable screws compared with fixation with suture anchors and transosseous sutures. Results: In the in vivo portion of the study, the cohort treated with the Headed Bio-Corkscrew demonstrated no improvement on any measured parameter until 1-year after rotator cuff repair. In contrast, shoulders repaired with Mitek Rotator Cuff QuickAnchors demonstrated improved overall shoulder function as early as 6 weeks postoperatively (P = .002); had a better constant score at 1-year after repair (88 +/- 9 v 73 +/- 17; P = .016), and a lower rate of revision rotator cuff repair (P = .029). In the ex vivo portion of the study, the bioabsorbable headed screws, Headed Bio-Corkscrew (100 +/- 30 N) and BioTwist (76 +/- 35 N), had inferior initial failure load properties compared with suture anchors (140 +/- 36 N) and transosseous sutures (147 +/- 68 N). In contrast, the BioCuff (190 +/- 56 N), a bioabsorbable implant that used a screw and serrated washer design, had equivalent initial failure load properties as the suture repairs. Conclusions: This investigation had poorer early outcomes, a lower shoulder functional score 1-year after repair, and a higher rate of repeat surgery in patients who had their rotator cuff repaired with a bioabsorbable screw than in patients who had their shoulders repaired with a standard metal suture anchor. Furthermore, the biomechanical testing demonstrated a lower tensile load to failure in the tendons repaired with a simple screw design compared to suture anchors with a mattress stitch. Of note, the implant that used a screw and washer design demonstrated a greater ability to resist initial tensile load.
引用
收藏
页码:239 / 248
页数:10
相关论文
共 22 条
[1]
Böstman OM, 2000, CLIN ORTHOP RELAT R, P216
[2]
Strength of fixation with transosseous sutures in rotator cuff repair [J].
Caldwell, GL ;
Warner, JJP ;
Miller, MD ;
Boardman, D ;
Towers, J ;
Debski, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (07) :1064-1068
[3]
TENDONS, LIGAMENTS, AND CAPSULE OF THE ROTATOR CUFF - GROSS AND MICROSCOPIC ANATOMY [J].
CLARK, JM ;
HARRYMAN, DT .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (05) :713-725
[4]
Surgical repair of chronic rotator cuff tears - A prospective long-term study [J].
Cofield, RH ;
Parvizi, J ;
Hoffmeyer, PJ ;
Lanzer, WL ;
Ilstrup, DM ;
Rowland, CM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (01) :71-77
[5]
CONSTANT CR, 1987, CLIN ORTHOP RELAT R, P160
[6]
CUMMINS CA, 2002, M AM AC ORTH SURG DA
[7]
Early effectiveness of arthroscopic repair for full-thickness tears of the rotator cuff - An outcome analysis [J].
Gartsman, GM ;
Brinker, MR ;
Khan, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (01) :33-40
[8]
Arthroscopic repair of full-thickness tears of the rotator cuff [J].
Gartsman, GM ;
Khan, M ;
Hammerman, SM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (06) :832-840
[9]
GAZIELLY DF, 1994, CLIN ORTHOP RELAT R, V304, P43
[10]
Experimental rotator cuff repair - A preliminary study [J].
Gerber, C ;
Schneeberger, AG ;
Perren, SM ;
Nyffeler, RW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (09) :1281-1290