Assessing agreement between measurements recorded on a ratio scale in sports medicine and sports science

被引:269
作者
Nevill, AM [1 ]
Atkinson, G [1 ]
机构
[1] Liverpool John Moores Univ, Sch Human Sci, Ctr Sport & Exercise Sci, Liverpool L3 3AK, Merseyside, England
关键词
heteroscedastic errors; ratio limits of agreement; dimensionless ratio;
D O I
10.1136/bjsm.31.4.314
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Objective-The consensus of opinion suggests that when assessing measurement agreement, the most appropriate statistic to report is the "95% Limits of agreement". The precise form that this interval takes depends on whether a positive relation exists between the differences in measurement methods (errors) and the size of the measurements-that is, heteroscedastic errors. If a positive and significant relation exists, the recommended procedure is to report "the ratio limits of agreement" using log transformed measurements. This study assessed the prevalence of heteroscedastic errors when investigating measurement agreement of variables recorded on a ratio scale in sports medicine and sports science. Methods-Measurement agreement (or repeatability) was assessed in 13 studies (providing 23 examples) conducted in the Centre for Sport and Exercise Sciences at Liverpool John Moores University over the past five years. Results-The correlation between the absolute differences and the mean was positive in all 23 examples (median r=0.37), eight being significant (P<0.05). In 21 of 23 examples analysed, the correlation was greater than the equivalent correlation using log transformed measurements (median r=0.01). Based on a simple metaanalysis, the assumption that no relation exists between the measurement differences and the size of measurement must be rejected (P<0.001). Conclusions-When assessing measurement agreement of variables recorded on a ratio scale in sports medicine and sports science, this study (23 examples) provides strong evidence that heteroscedastic errors are the norm. If the correlation between the absolute measurement differences and the means is positive (but not necessarily significant) and greater than the equivalent correlation using log transformed measurements, the authors recommend reporting the "ratio limits of agreement".
引用
收藏
页码:314 / 318
页数:5
相关论文
共 8 条
[1]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]  
Atkinson G., 1995, SPORT LEISURE ERGONO, P218
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]  
BLAND M, 1995, INTRO MED STAT, P269
[5]   ALLOMETRY EQUATION IN ANALYSIS OF STANDARD OXYGEN CONSUMPTION AND BODY WEIGHT OF WHITE RAT [J].
JOLICEUR, P ;
HEUSNER, AA .
BIOMETRICS, 1971, 27 (04) :841-&
[6]  
*MIN INC, 1995, MINITAB REF MAN
[7]   MODELING MAXIMUM OXYGEN-UPTAKE - A CASE-STUDY IN NONLINEAR-REGRESSION MODEL FORMULATION AND COMPARISON [J].
NEVILL, AM ;
HOLDER, RL .
APPLIED STATISTICS-JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES C, 1994, 43 (04) :653-666
[8]   SCALING PHYSIOLOGICAL MEASUREMENTS FOR INDIVIDUALS OF DIFFERENT BODY SIZE [J].
NEVILL, AM ;
RAMSBOTTOM, R ;
WILLIAMS, C .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1992, 65 (02) :110-117