Comparison of rigid and elastic matching of dynamic magnetic resonance mammographic images by mutual information

被引:20
作者
Brückner, T
Lucht, R
Brix, G
机构
[1] German Canc Res Ctr, Res Program Radiol Diag & Therapy, Heidelberg, Germany
[2] Fed Off Radiat Protect, Dept Med Radiat Hyg, Neuherberg, Germany
关键词
D O I
10.1118/1.1288241
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The present study aims at (i) the evaluation of the performance of a rigid and of an elastic matching algorithm for the coregistration of dynamic magnetic resonance (MR) images visualizing the female breast, and (ii) the evaluation of the mutual information (MI) as a matching criterion. To this end, ten patient data sets were analyzed. The comparison was performed with respect to the achieved increase in the MI and by visual inspection of the dynamic image series in a continuous film sequence (cine mode). In most cases, the achieved increase in MI by elastic image registration is much higher than that achieved by rigid registration. Only for three of the ten data sets could the MI be increased by rigid image registration to a similar or even larger degree than by elastic image registration. Taking into account the results of the visual inspection of the rigid and elastic matched data sets, however, the elastic match leads to equal or better results for all data sets. Therefore, elastic matching is the gold standard for the registration of dynamic MR mammographic images of the female breast. The comparison of the increase in MI and the visual inspection further shows that the visual impression agrees in most cases with the result of the calculation of the MI. Therefore, the MI proves to be a suitable matching criterion for the type of data sets studied. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)00309-6].
引用
收藏
页码:2456 / 2461
页数:6
相关论文
共 16 条
[1]   A COMPUTERIZED SYSTEM FOR THE ELASTIC MATCHING OF DEFORMED RADIOGRAPHIC IMAGES TO IDEALIZED ATLAS IMAGES [J].
BAJCSY, R ;
LIEBERSON, R ;
REIVICH, M .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1983, 7 (04) :618-625
[2]   A physics-based coordinate transformation for 3-D image matching [J].
Davis, MH ;
Khotanzad, A ;
Flamig, DP ;
Harms, SE .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (03) :317-328
[3]   OPTIMIZATION AND EVALUATION OF LANDMARK-BASED IMAGE CORRELATION [J].
ENDE, G ;
TREUER, H ;
BOESECKE, R .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (01) :261-271
[4]  
ENGLISH PT, 1995, MRI RADIOGRAPHERS, P164
[5]   PHARMACOKINETIC MAPPING OF THE BREAST - A NEW METHOD FOR DYNAMIC MR MAMMOGRAPHY [J].
HOFFMANN, U ;
BRIX, G ;
KNOPP, MV ;
HESS, T ;
LORENZ, WJ .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (04) :506-514
[6]  
KRENGEL U, 1990, EINFUHRUNG WAHRSCHEI
[7]  
Lucht R, 2000, MAGN RESON MED, V43, P9, DOI 10.1002/(SICI)1522-2594(200001)43:1<9::AID-MRM2>3.0.CO
[8]  
2-C
[9]   Multimodality image registration by maximization of mutual information [J].
Maes, F ;
Collignon, A ;
Vandermeulen, D ;
Marchal, G ;
Suetens, P .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) :187-198
[10]   ACCURATE 3-DIMENSIONAL REGISTRATION OF CT, PET, AND OR MR IMAGES OF THE BRAIN [J].
PELIZZARI, CA ;
CHEN, GTY ;
SPELBRING, DR ;
WEICHSELBAUM, RR ;
CHEN, CT .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (01) :20-26