Clinical potentials of the prototype 256-detector row CT-scanner

被引:35
作者
Mori, S
Endo, M
Obata, T
Murase, K
Fujiwara, H
Susumu, K
Tanada, S [1 ]
机构
[1] Natl Inst Radiol Sci, Dept Med Imaging, Chiba 2638555, Japan
[2] Natl Inst Radiol Sci, Dept Phys Med, Chiba 2638555, Japan
[3] Natl Inst Radiol Sci, Res Ctr Hosp Charged Particle Therapy, Chiba 2638555, Japan
[4] Osaka Univ, Fac Med, Sch Allied Hlth Sci, Osaka 5650871, Japan
关键词
computed tomography; cone-beam; image quality; four-dimensional;
D O I
10.1016/j.acra.2004.11.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. To evaluate clinical potentials of the 256-detector row computed tomography (CT) in healthy volunteers. Materials and Methods. Eight healthy males (22-63 years) participated in the present study. They underwent a non-contrast-enhanced examination with a contiguous axial scan mode either for head, chest, abdomen, or pelvis. Dose was the same as routinely used for multislice CT examinations. Image quality was interpreted by three board-certitied radiologists. Results. With the 256-detector row CT, 0.5-0.8 mm isotropic volumetric data could be acquired in one rotation. Main promising findings are as follows. Three-dimensional structures were visualized clearly in the multiple planes without secondary reconstruction, whereas the axial images had nearly the same image quality as conventional CT. Shading or streak artifacts were observed at the edge of the scan region. The latter are also known as Feldkamp artifacts. Coronal chest images showed a motion artifact from the heart beating. Conclusion. The 256-detector row CT promises to be useful in clinical applications with its ability to provide three-dimensional visualization of fine structures. The Feldkamp artifacts observed did not generally affect interpretation of images. Investigations are now continuing on image correction along the craniocaudal direction to improve the overall image quality.
引用
收藏
页码:148 / 154
页数:7
相关论文
共 14 条
[1]   Development and performance evaluation of the first model of 4-D CT-scanner [J].
Endo, M ;
Mori, S ;
Tsunoo, T ;
Kandatsu, S ;
Tanada, S ;
Aradate, H ;
Saito, Y ;
Miyazaki, H ;
Satoh, K ;
Matsusita, S ;
Kusakabe, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) :1667-1671
[2]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[3]  
FUNABASHI N, IN PRESS J CARDIOL
[4]  
JIANG H, 2000, IEEE MED IMAG, V15, P71
[5]   Advanced single-slice rebinning in cone-beam spiral CT [J].
Kachelriess, M ;
Schaller, S ;
Kalender, WA .
MEDICAL PHYSICS, 2000, 27 (04) :754-772
[6]   Extended parallel backprojection for standard three-dimensional and phase-correlated four-dimensional axial and spiral cone-beam CT with arbitrary pitch, arbitrary cone-angle, and 100% dose usage [J].
Kachelriess, M ;
Knaup, M ;
Kalender, WA .
MEDICAL PHYSICS, 2004, 31 (06) :1623-1641
[7]   Theoretically exact filtered backprojection-type inversion algorithm for spiral CT [J].
Katsevich, A .
SIAM JOURNAL ON APPLIED MATHEMATICS, 2002, 62 (06) :2012-2026
[8]  
Katsevich A, 2003, INT J MATH MATH SCI, V2003, DOI DOI 10.1155/S0161171203209315
[9]  
MOCHIZUKI T, 2003, RADIOLOGY S, P541
[10]   Physical performance evaluation of a 256-slice CT-scanner for four-dimensional imaging [J].
Mori, S ;
Endo, M ;
Tsunoo, T ;
Kandatsu, S ;
Tanada, S ;
Aradate, H ;
Saito, Y ;
Miyazaki, H ;
Satoh, K ;
Matsushita, S ;
Kusakabe, M .
MEDICAL PHYSICS, 2004, 31 (06) :1348-1356