Simulation of hybrid renewable microgeneration systems for variable electricity prices

被引:33
作者
Brandoni, C. [1 ]
Renzi, M. [2 ]
Caresana, F. [3 ]
Polonara, F. [3 ]
机构
[1] Univ E Campus, I-22060 Novedrate, CO, Italy
[2] Libera Univ Bolzano, I-39100 Bolzano, Italy
[3] Univ Politecn Marche, Dipartimento Ingn Ind & Sci Matemat, I-60131 Ancona, Italy
关键词
Micro-CHP; Solar systems; HCPV; PV; Multi-objective linear optimization; Hybrid renewable systems; INTERNAL-COMBUSTION ENGINE; MICRO-CHP SYSTEMS; ENERGY; PERFORMANCE; BUILDINGS; MODEL;
D O I
10.1016/j.applthermaleng.2013.10.044
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper addresses a hybrid renewable system that consists of a micro-Combined Cooling Heat and Power (CCHP) unit and a solar energy conversion device. In addition to a traditional PV system, a High Concentrator Photovoltaic (HCPV) device, the design of which is suitable for building integration application, was also modelled and embedded in the hybrid system. The work identifies the optimal management strategies for the hybrid renewable system in an effort to minimise the primary energy usage, the carbon dioxide emissions and the operational costs for variable electricity prices that result from the day-ahead electricity market. An "ad hoc" model describes the performance of the HCPV module, PV and Internal Combustion Engine, whilst the other units were simulated based on their main characteristic parameters. The developed algorithm was applied to three different building typologies. The results indicate that the best configuration is the hybrid renewable system with PV, which can provide a yearly primary energy reduction of between 20% and 30% compared to separate production. The hybrid renewable system with HCPV becomes competitive with the PV technology when the level of solar radiation is high. (C) 2013 Elseider Ltd. All rights reserved.
引用
收藏
页码:667 / 676
页数:10
相关论文
共 39 条
[1]   Distributed microtrigeneration systems [J].
Angrisani, G. ;
Roselli, C. ;
Sasso, M. .
PROGRESS IN ENERGY AND COMBUSTION SCIENCE, 2012, 38 (04) :502-521
[2]   Experimental results of a micro-trigeneration installation [J].
Angrisani, G. ;
Rosato, A. ;
Roselli, C. ;
Sasso, M. ;
Sibilio, S. .
APPLIED THERMAL ENGINEERING, 2012, 38 :78-90
[3]  
[Anonymous], 2012, PV GRID PARITY MONIT
[4]  
[Anonymous], 2003, NATL PLAN GHG EMISSI
[5]   A model for micro-trigeneration systems based on linear optimization and the Italian tariff policy [J].
Arosio, Sergio ;
Guilizzoni, Manfredo ;
Pravettoni, Francesca .
APPLIED THERMAL ENGINEERING, 2011, 31 (14-15) :2292-2300
[6]   Domestic demand-side management (DSM): Role of heat pumps and thermal energy storage (TES) systems [J].
Arteconi, A. ;
Hewitt, N. J. ;
Polonara, F. .
APPLIED THERMAL ENGINEERING, 2013, 51 (1-2) :155-165
[7]   Validated real-time energy models for small-scale grid-connected PV-systems [J].
Ayompe, L. M. ;
Duffy, A. ;
McCormack, S. J. ;
Conlon, M. .
ENERGY, 2010, 35 (10) :4086-4091
[8]   Theoretical derivation of heliostat tracking errors distribution [J].
Badescu, Viorel .
SOLAR ENERGY, 2008, 82 (12) :1192-1197
[9]   Analysis of innovative micro-CHP systems to meet household energy demands [J].
Barbieri, Enrico Saverio ;
Spina, Pier Ruggero ;
Venturini, Mauro .
APPLIED ENERGY, 2012, 97 :723-733
[10]  
Bowen A., 2011, POLICY BRIED