Concurrent related validity of the GAITRite® walkway system for quantification of the spatial and temporal parameters of gait

被引:557
作者
Bilney, B [1 ]
Morris, M
Webster, K
机构
[1] La Trobe Univ, Sch Physiotherapy, Bundoora, Vic 3083, Australia
[2] La Trobe Univ, Musculoskeletal Res Ctr, Bundoora, Vic 3083, Australia
[3] La Trobe Univ, Musculoskeletal Res Ctr, Bundoora, Vic 3083, Australia
关键词
gait; locomotion; measurement; adults;
D O I
10.1016/S0966-6362(02)00053-X
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The GAITRite(R) is a portable gait analysis tool for automated measurement of spatiotemporal gait parameters. Although frequently used for clinical and research purposes, the concurrent validity of GAITRite(R) has not been validated against a criterion measure. The aim of this experiment was to investigate the concurrent validity and test retest reliability of the GAITRite(R) carpet walkway system for quantification of spatial and temporal parameters of the footstep pattern. Twenty-five healthy adults aged 21 71 years (mean 40.5 years, S.D. 17.2) performed three walk trials at self-selected pace, three at fast pace and three at slow pace. For each trial, data were simultaneously collected from the GAITRite(R) and a Clinical Stride Analyzer(R), which has established reliability and validity. At preferred, slow and fast walking pace there were very high correlations between the two measurement systems for gait speed (ICC (2, 1) = 0.99), stride length (ICC (2, 1) = 0.99) and cadence (ICC (2, 1) = 0.99). Correlations between the electronic carpet and the stride analyser were moderate to high for single limb support (SLS) time (ICC (2, 1) = 0.69-0.91) and weak for the proportion of the gait cycle spent in double limb support (ICC (2,1) = 0.44-0.57). The reliability of repeated measures for the GAITRite(R) was good at preferred and fast speed for speed (ICC (3,l) = 0.93-0.94), cadence (ICC (3,1) = 0.92-0.94), stride length (ICC (3, 1) = 0.97), single support (ICC (3, 1) = 0.85-0.93) and the proportion of the gait cycle spent in double limb support (ICC (3,1) = 0.89-0.92). The repeatability of the GAITRite(R) measures were more variable at slow speed (ICC (3,l) = 0.76-0.91). These results indicate that the GAITRite(R) system has strong concurrent validity and test retest reliability, in addition to being a portable, simple clinical tool for the objective assessment of gait. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:68 / 74
页数:7
相关论文
共 35 条
[1]  
[Anonymous], J ORTHOP SPORTS PHYS
[2]   Goal-directed secondary motor tasks: Their effects on gait in subjects with Parkinson disease [J].
Bond, JM ;
Morris, M .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2000, 81 (01) :110-116
[3]  
CHEN FC, 1998, PHYS THER, V78, pS68
[4]  
CHURCHYARD A, 2001, GAIT DISORDERS ADV N
[5]   ABSORBENT PAPER METHOD FOR RECORDING FOOT PLACEMENT DURING GAIT - SUGGESTION FROM THE FIELD [J].
CLARKSON, BH .
PHYSICAL THERAPY, 1983, 63 (03) :345-346
[6]   Evaluation of an instrumented walkway for measurement of the kinematic parameters of gait [J].
Cutlip, RG ;
Mancinelli, C ;
Huber, F ;
DiPasquale, J .
GAIT & POSTURE, 2000, 12 (02) :134-138
[7]   INTERRATER RELIABILITY OF VIDEOTAPED OBSERVATIONAL GAIT-ANALYSIS ASSESSMENTS [J].
EASTLACK, ME ;
ARVIDSON, J ;
SNYDERMACKLER, L ;
DANOFF, JV ;
MCGARVEY, CL .
PHYSICAL THERAPY, 1991, 71 (06) :465-472
[8]   Systematic and random error in repeated measurements of temporal and distance parameters of gait after stroke [J].
Evans, MD ;
Goldie, PA ;
Hill, KD .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1997, 78 (07) :725-729
[9]  
GAUDET G, 1990, Physiotherapy Canada, V42, P12
[10]   RELIABILITY AMONG PHYSICAL THERAPISTS IN DIAGNOSIS AND TREATMENT OF GAIT DEVIATIONS IN HEMIPLEGICS [J].
GOODKIN, R ;
DILLER, L .
PERCEPTUAL AND MOTOR SKILLS, 1973, 37 (03) :727-734