UV inactivation, liquid-holding recovery, and photoreactivation of Escherichia coli O157 and other pathogenic Escherichia coli strains in water

被引:151
作者
Sommer, R [1 ]
Lhotsky, M
Haider, T
Cabaj, A
机构
[1] Univ Vienna, Inst Hyg, A-1010 Vienna, Austria
[2] Univ Vienna, Inst Environm Hyg, A-1010 Vienna, Austria
[3] Univ Vet Med, Inst Med Phys & Biostat, Vienna, Austria
关键词
D O I
10.4315/0362-028X-63.8.1015
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Drinking water, water used in food production and for irrigation, water for fish farming, waste water, surface water, and recreational water have been recently recognized as a vector for the transmission of pathogenic Escherichia coli, especially serotype O157:H7. We investigated the UV (253.7 nm) inactivation behavior and the capability of dark repair (liquid-holding recovery) and photoreactivation of seven pathogenic (including three enterohemorrhagic E. coli) strains and one nonpathogenic strain of E. coli (ATCC 11229) with respect to the use of UV light for water disinfection purposes. Because most bacteria and yeast are known to be able to repair UV damage in their nucleic acids, repair mechanisms have to be considered to ensure safe water disinfection. We found a wide divergence in the UV susceptibility within the strains tested. A 6-log reduction of bacteria that fulfills the requirement for safe water disinfection was reached for the very most susceptible strain O157:H7 (CCUG 29199) at a UV fluence of 12 J/m(2), whereas for the most resistant strain, O25:K98:NM, a UV fluence of about 125 J/m(2) was needed. Except for one strain (O50:H7) liquid-holding recovery did not play an important role in recovery after UV irradiation. By contrast, ail strains, particularly strains O25:K98:NM, O78:K80:H12, and O157:H7 (CCUG 29193), demonstrated photorepair ability. For a 6-log reduction of these strains, a UV fluence (253.7 nm) up to 300 J/m(2) is required. The results reveal that the minimum fluence of 400 J/m(2) demanded in the Austrian standard for water disinfection is sufficient to inactivate pathogenic E, coli. A fluence of 160 J/m(2) (recommendation in Norway) or 250 J/m(2) (recommendation in Switzerland) cannot be regarded as safe in that respect.
引用
收藏
页码:1015 / 1020
页数:6
相关论文
共 25 条
[1]  
AKASHI S, 1994, EUR J PEDIATR, V153, P650, DOI 10.1007/BF02190685
[2]  
*AUSTR NAT STAND, 1996, 5873 M AUSTR NAT STR
[3]  
BINDER HJ, 1995, GASTROENTEROLOGY, V108, P1597
[4]   Biodosimetry: Model calculations for uv water disinfection devices with regard to dose distributions [J].
Cabaj, A ;
Sommer, R ;
Schoenen, D .
WATER RESEARCH, 1996, 30 (04) :1003-1009
[5]   WATERBORNE OUTBREAK OF ESCHERICHIA-COLI O157 [J].
DEV, VJ ;
MAIN, M ;
GOULD, I .
LANCET, 1991, 337 (8754) :1412-1412
[6]  
Doyle M. P., 1997, FOOD MICROBIOLOGY FU
[7]  
*DVGW, 1997, 294 DVGW W
[9]   ULTRAVIOLET INACTIVATION OF SELECTED BACTERIA AND VIRUSES WITH PHOTOREACTIVATION OF THE BACTERIA [J].
HARRIS, GD ;
ADAMS, VD ;
SORENSEN, DL ;
CURTIS, MS .
WATER RESEARCH, 1987, 21 (06) :687-692
[10]   Chlorination of pathogenic E coli O157 [J].
Kaneko, M .
WATER SCIENCE AND TECHNOLOGY, 1998, 38 (12) :141-144