A generalized performance prediction method for adiabatic capillary tubes

被引:42
作者
Bittle, RR [1 ]
Wolf, DA
Pate, MB
机构
[1] Texas Christian Univ, Dept Engn, Ft Worth, TX 76129 USA
[2] JL Hall Engn Serv, Ames, IA USA
[3] Iowa State Univ, Dept Mech Engn, Ames, IA 50011 USA
来源
HVAC&R RESEARCH | 1998年 / 4卷 / 01期
关键词
D O I
10.1080/10789669.1998.10391389
中图分类号
O414.1 [热力学];
学科分类号
摘要
Generalized dimensionless correlations were developed to predict refrigerant mass flow rate in an adiabatic capillary tube, for both subcooled and quality inlet conditions. Dimensionless parameters were created using the Buckingham Pi Theorem. These parameters were based on the effects of tube geometry, inlet conditions, and fluid properties. The correlations were based on experimental performance data with refrigerants R-134a, R-22, and R-410A that encompass an extensive range of operating conditions, including: condensing temperatures from 79 degrees F to 127 degrees F (26 degrees C to 53 degrees C), capillary tube inner diameters from 0.026 to 0.090 in (0.66 to 2.29 mm), capillary tube lengths from 20 to 200 in (508 to 5080 mm), and inlet conditions from 30 degrees F (16.7 degrees C) subcooled to 35% quality. Corresponding to this range of refrigerants, capillary tube geometry, and operating conditions, the experimental mass flow rate range was between 3 and 375 lb(m)/h (1.4 to 170 kg/h). Independent assessments of both correlations were made by comparing predictions to measured performance with R-152a. These data fell within the +/-6% and +/-13% prediction intervals for the subcooled inlet and quality inlet correlations, respectively. The accuracy of the subcooled inlet correlation was further assessed by comparing predicted performance to measured data reported by other investigators with refrigerants R-12, R-134a, and R-22. it was shown that the subcooled inlet correlation predicted the bulk of these flow data to within +/-10%. However, when compared to reported data with R-600a (isobutane), however, the subcooled inlet correlation over-predicted mass flow rate by 0 to 20%.
引用
收藏
页码:27 / 43
页数:17
相关论文
共 22 条
[1]  
[Anonymous], 1957, REFRIGERAT ENG
[2]  
*ASHRAE, 1996, 281996 ANSI ASHRAE
[3]  
ASHRAE, 1994, ASHRAE HDB REFR SYST
[4]  
Bittle RR, 1996, ASHRAE TRAN, V102, P52
[5]  
BOLSTAD MM, 1948, REFRIGERATING ENG, P519
[6]   On physically similar systems, illustrations of the use of dimensional equations [J].
Buckingham, E .
PHYSICAL REVIEW, 1914, 4 (04) :345-376
[7]  
Cooper L., 1957, REF ENG, V65, P37
[8]  
Fox R.W., 1992, Introduction to Fluid Mechanics, Vfourth
[9]  
HOPKINS NE, 1950, REFRIGERATING EN NOV, P1087
[10]  
Inan C., 1994, P 1994 INT REFR C PU, P365