Mathematical model developed for environmental samples: Prediction of GC/MS dioxin TEQ from XDS-CALUX bioassay data

被引:15
作者
Brown, David J.
Orelien, Jean
Gordon, John D.
Chu, Andrew C.
Chu, Michael D.
Nakamura, Masafumi
Handa, Hiroshi
Kayama, Fujio
Denison, Michael S.
Clark, George C.
机构
[1] Xenobiot Detect Syst, Durham, NC 27704 USA
[2] Marietta Coll, Marietta, OH 45750 USA
[3] SciMetrika LLC, Res Triangle Pk, NC 27709 USA
[4] Analyt Perspect, Wilmington, NC 28405 USA
[5] Hiyoshi Corp, Shiga 5238555, Japan
[6] Jichi Med Univ, Ctr Community Med, Dept Environm Med, Tochigi 3290498, Japan
[7] Univ Calif Davis, Dept Environm Toxicol, Davis, CA 95616 USA
关键词
D O I
10.1021/es062602+
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Remediation of hazardous waste sites requires efficient and cost-effective methods to assess the extent of contamination by toxic substances including dioxin-like chemicals. Traditionally, dioxin-like contamination has been assessed by gas chromatography/high-resolution mass spectrometry (GC/MS) analysis for specific polychlorinated dibenzo-p-dioxins, dibenzofurans, and biphenyl congeners. Toxic equivalency factors for these congeners are then used to estimate the overall dioxin toxic equivalency (TEQ) of complex mixtures found in samples. The XDS-CALUX bioassay estimates contamination by dioxin-like chemicals in a sample extract by measuring expression of a sensitive reporter gene in genetically engineered cells. The output of the XDS-CALUX assay is a CALUX-TEQ value, calibrated based on TCDD standards. Soil samples taken from a variety of hazardous waste sites were measured using the XDS-CALUX bioassay and GC/MS. TEQ and CALUX-TEQ from these methods were compared, and a mathematical model was developed describing the relationship between these two data sets: log(TEQ) = 0.654 x log(CALUX-TEQ) + 0.058(log(CALUX-TEQ))(2). Applying this equation to these samples showed that predicted and GC/MS measured TEQ values strongly correlate (R-2 = 0.876) and that TEQ values predicted from CALUX-TEQ were on average nearly identical to the GC/MS-TEQ. The ability of XDS-CALUX bioassay data to predict GC/MS-derived TEQ data should make this procedure useful in risk assessment and management decisions.
引用
收藏
页码:4354 / 4360
页数:7
相关论文
共 41 条
[1]   Brominated dioxin-like compounds: in vitro assessment in comparison to classical dioxin-like compounds and other polyaromatic compounds [J].
Behnisch, PA ;
Hosoe, K ;
Sakai, S .
ENVIRONMENT INTERNATIONAL, 2003, 29 (06) :861-877
[2]  
Besselink H., 2003, ORGANOHALOGEN COMPOU, V60, P203
[3]   TEFs: A practical approach to a real-world problem [J].
Birnbaum, LS .
HUMAN AND ECOLOGICAL RISK ASSESSMENT, 1999, 5 (01) :13-24
[4]   THE MECHANISM OF DIOXIN TOXICITY - RELATIONSHIP TO RISK ASSESSMENT [J].
BIRNBAUM, LS .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1994, 102 :157-167
[5]  
Brown D., 2000, ORGANOHALOGEN COMPOU, V45, P200
[6]  
Brown D. J., 2001, ORGANOHALOGEN COMPD, V54, P32
[7]  
Brown D.J., 2002, ORGANOHALOGEN COMPD, V58, P357
[8]   Analysis of Ah receptor pathway activation by brominated flame retardants [J].
Brown, DJ ;
Van Overmeire, I ;
Goeyens, L ;
Denison, MS ;
De Vito, MJ ;
Clark, GC .
CHEMOSPHERE, 2004, 55 (11) :1509-1518
[9]  
Brown DJ, 2002, ORGANOHALOGEN COMPD, V58, P401
[10]  
Brown DJ, 2001, ORGANOHALOGEN COMPD, V53, P211