Rapid and direct estimation of active biomass on granular activated carbon through adenosine tri-phosphate (ATP) determination

被引:173
作者
Velten, Silvana [1 ]
Hammes, Frederik [1 ]
Boller, Markus [1 ]
Egli, Thomas [1 ]
机构
[1] Swiss Fed Inst Aquat Sci & Technol, Eawag, CH-8600 Dubendorf, Switzerland
关键词
ATP; biomass; granular activated carbon (GAC); drinking water;
D O I
10.1016/j.watres.2007.01.021
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Granular activated carbon (GAC) filtration is used during drinking water treatment for the removal of micropollutants such as taste and odour compounds, halogenated hydrocarbons, pesticides and pharmaceuticals. In addition, the active microbial biomass established on GAC is responsible for the removal of biodegradable dissolved organic carbon compounds present in water or formed during oxidation (e.g., ozonation and chlorination) processes. In order to conduct correct kinetic evaluations of DOC removal during drinking water treatment, and to assess the state and performance of full-scale GAC filter installations, an accurate and sensitive method for active biomass determination on GAC is required. We have developed a straight-forward method based on direct measurement of the total adenosine tri-phosphate (ATP) content of a GAC sample and other support media. in this method, we have combined flow-cytometric absolute cell counting and ATP analysis to derive case-specific ATP/cell conversion values. In this study, we present the detailed standardisation of the ATP method. An uncertainty assessment has shown that heterogeneous colonisation of the GAC particles makes the largest contribution to the combined standard uncertainty of the method. The method was applied for the investigation of biofilm formation during the start-up period of a GAC pilot-scale plant treating Lake Zurich water. A rapid increase in the biomass of up to 1.1 x 10(10) cells/g GAC dry weight (DW) within the first 33 days was observed, followed by a slight decrease to an average steady-state concentration of 7.9 x 10(9) cells/g GAC DW. It was shown that the method can be used to determine the biomass attached to the GAC for both stable and developing biofilms. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1973 / 1983
页数:11
相关论文
共 30 条
[1]  
Ahmad R, 1998, J AM WATER WORKS ASS, V90, P62
[2]  
[Anonymous], EURACHEM
[3]   ADENYLATE ENERGY CHARGE IN ESCHERICHIA-COLI DURING GROWTH AND STARVATION [J].
CHAPMAN, AG ;
FALL, L ;
ATKINSON, DE .
JOURNAL OF BACTERIOLOGY, 1971, 108 (03) :1072-+
[4]  
DEWATERS JE, 1990, J AM WATER WORKS ASS, V82, P69
[5]  
Escobar IC, 2001, J AM WATER WORKS ASS, V93, P77
[6]   Comparative measurements of microbial activity in drinking water biofilters [J].
Fonseca, AC ;
Summers, RS ;
Hernandez, MT .
WATER RESEARCH, 2001, 35 (16) :3817-3824
[7]   New method for assimilable organic carbon determination using flow-cytometric enumeration and a natural microbial consortium as inoculum [J].
Hammes, FA ;
Egli, T .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (09) :3289-3294
[8]   Mechanistic and kinetic evaluation of organic disinfection by-product and assimilable organic carbon (AOC) formation during the ozonation of drinking water [J].
Hammes, Frederik ;
Salhi, Elisabeth ;
Koester, Oliver ;
Kaiser, Hans-Peter ;
Egli, Thomas ;
von Gunten, Urs .
WATER RESEARCH, 2006, 40 (12) :2275-2286
[9]   CONTROL OF RESPIRATION AND METABOLISM IN GROWIG KLEBSIELLA AEROGENES - ROLE OF ADENINE NUCLEOTIDES [J].
HARRISON, DE ;
MAITRA, PK .
BIOCHEMICAL JOURNAL, 1969, 112 (05) :647-&
[10]   A LIQUID-CHROMATOGRAPHIC SYSTEM WITH MULTI-DETECTION FOR THE DIRECT ANALYSIS OF HYDROPHILIC ORGANIC-COMPOUNDS IN NATURAL-WATERS [J].
HUBER, S ;
FRIMMEL, FH .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (1-2) :198-200