The open section effect in a long bone with a longitudinal defect - a theoretical modeling study

被引:27
作者
Elias, JJ [1 ]
Frassica, FJ [1 ]
Chao, EYS [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, Orthopaed Biomech Lab, Baltimore, MD 21205 USA
关键词
bone defect; torsion; finite element analysis; open-section effect;
D O I
10.1016/S0021-9290(00)00107-X
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
A longitudinal defect dramatically alters the stress distribution within a long bone. The altered stress distribution can influence the structural properties of the bone and the stimulus for repair and remodeling of the defect and the surrounding bone. For applied torsion, the defect interrupts the normal shear flow around the bone. Reversal of the shear flow along the inner cortex of the bone is the primary characteristic of the "open-section" effect. Stress concentration effects also produce large stresses at the defect corners. A finite element model of a femur mid-diaphysis with a rectangular defect in the posterior cortex was developed to quantify the femur stress distribution and torsional stiffness for defect widths ranging from one-tenth of the femur outer diameter (0.1 OD) to 0.3 OD, and defect lengths ranging from 0.5 to 5 OD. Defects with a length of 1 OD or shorter had little influence on the femur torsional stiffness or the femur shear-stress distribution. The torsional stiffness decreased most dramatically as the defect length increased from 2 to 3 OD, but began to approach an asymptote near 5 OD. Shear flow reversal peaked at the center of the defect for defects longer than 1 OD, and the magnitude of the reversal began to approach an asymptote near 5 OD. For each defect, the largest stresses within the bone, developed at the defect corners. The results indicate that the open-section effect decreases the torsional stiffness and stress concentration effects decrease the torsional strength of a long bone with a longitudinal defect. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1517 / 1522
页数:6
相关论文
共 20 条
[1]
Aoyama K, 1994, CLIN BIOMECHANICS RE, P34
[2]
BIOMECHANICS OF TORSIONAL FRACTURES - STRESS CONCENTRATION EFFECT OF A DRILL HOLE [J].
BROOKS, DB ;
BURSTEIN, AH ;
FRANKEL, VH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1970, A 52 (03) :507-&
[3]
EFFECT OF BIOPSY-HOLE SHAPE AND SIZE ON BONE STRENGTH [J].
CLARK, CR ;
MORGAN, C ;
SONSTEGARD, DA ;
MATTHEWS, LS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (02) :213-217
[4]
DESOUZA ML, 1989, P 35 ANN M ORTH RES
[5]
TORSIONAL STRENGTH REDUCTION DUE TO CORTICAL DEFECTS IN BONE [J].
EDGERTON, BC ;
AN, KN ;
MORREY, BF .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1990, 8 (06) :851-855
[6]
ELIAS JJ, 1998, P 44 ANN M ORTH RES
[7]
FRANKEL VH, 1970, ORTHOPAEDIC BIOMECHA, P74
[8]
FRANKEL VH, 1964, BIOMECHANICS RELATED, P381
[9]
FROST HM, 1983, CLIN ORTHOP RELAT R, P286
[10]
A UNIFYING PRINCIPLE RELATING STRESS TO TRABECULAR BONE MORPHOLOGY [J].
FYHRIE, DP ;
CARTER, DR .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1986, 4 (03) :304-317