Structural behaviour in fire compartment under different heating regimes - Part 1 (slab thermal gradients)

被引:33
作者
Sanad, AM [1 ]
Lamont, S [1 ]
Usmani, AS [1 ]
Rotter, JM [1 ]
机构
[1] Univ Edinburgh, Dept Civil & Environm Engn, Edinburgh EH9 3JN, Midlothian, Scotland
关键词
restrained composite beam; finite element modelling; thermal bowing;
D O I
10.1016/S0379-7112(00)00024-2
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Modelling the full-scale Fire Tests at Cardington has led to new understanding of the behaviour of structures under file conditions. Much of this understanding has come from parametric explorations using models verified against the tests. The structural phenomena observed in highly redundant, composite structures, during a compartment fire are dominated by restrained thermal expansion. The large deflections experienced in the structural elements in the region of the fire art: almost entirely attributable to thermally induced strains. The mechanisms responsible for producing these large deflections are restrained thermal expansion and thermal bowing. Material degradation and loading an secondary influences. A clear understanding of the response of the structure to an average temperature increase and through depth temperature gradients is essential. This paper discusses the structural response when subjected to different heating regimes obtained by changing the mean temperature and temperature gradient applied in the concrete slab of the composite floor slab system to a computer model of the British Steel restrained beam test. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:99 / 116
页数:18
相关论文
共 13 条
[1]  
*ABAQUS, 1994, ABAQUS THEOR MAN US
[2]  
BRAVERY PNR, 1994, CARDINGTON LARGE BUI
[3]  
*ENV, 1995, 199312 ENV
[4]  
ENV, 1995, Eurocode 2, Design of Concrete Structures, Part 1-2: GeneranRules structure fire Design, S. ENV. 1992-1-2
[5]  
*ENV, 1994, 199411 ENV
[6]  
KIRBY BR, 1997, 5 INT S FIR SAF SCI
[7]  
ROTTER JM, 1999, P INT 99 8 INT FIR S, V2, P1069
[8]   Structural behaviour in fire compartment under different heating regimes - part 2: (slab mean temperatures) [J].
Sanad, AM ;
Lamont, S ;
Usmani, AS ;
Rotter, JM .
FIRE SAFETY JOURNAL, 2000, 35 (02) :117-130
[9]  
SANAD AM, 1999, R99MD1 U ED DEP CIV
[10]  
SANAD AM, 2000, R00MD10 U ED DEP CIV