Effect of the glass surface modification on the strength of methacrylate monolith attachment

被引:41
作者
Vidic, J [1 ]
Podgornik, A [1 ]
Strancar, A [1 ]
机构
[1] BIA Separat DOO, SI-1000 Ljubljana, Slovenia
关键词
silanization; covalent attachment; monoliths; capillary columns;
D O I
10.1016/j.chroma.2004.11.044
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The influence of glass surface modification in order to determine strength of the monolith attachment was studied. Modification consists of pre-treatment of the glass with chemicals or boiling in deionized water, silanization and drying has been investigated on different types of glass. Amount of silane groups was determined by measurement of the contact angle between the glass surface and water drop. The highest values were found for soda-lime glass. Strength of the monolith attachment was established by pumping ethanol through the monolithic capillaries and measuring the pressure drop at which monolith was dislodged. Surprisingly, it was found that the critical part of the glass surface modification procedure is glass pre-treatment. Good results were obtained with glass boiled in water for 2.5 h or more. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:51 / 58
页数:8
相关论文
共 35 条
[1]   Wettability of silane-treated glass slides as determined from X-ray photoelectron spectroscopy [J].
Araujo, YC ;
Toledo, PG ;
Leon, V ;
Gonzalez, HY .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1995, 176 (02) :485-490
[2]  
Buszewski B, 2002, LC GC EUR, V15, P792
[3]  
D'Souza AS, 1999, J AM CERAM SOC, V82, P1289, DOI 10.1111/j.1151-2916.1999.tb01909.x
[4]   Preparation of continuous beds for electrochromatography and reversed-phase liquid chromatography of low-molecular-mass compounds [J].
Ericson, C ;
Liao, JL ;
Nakazato, K ;
Hjerten, S .
JOURNAL OF CHROMATOGRAPHY A, 1997, 767 (1-2) :33-41
[5]   Capillary columns with in situ formed porous monolithic packing for micro high-performance liquid chromatography and capillary electrochromatography [J].
Gusev, I ;
Huang, X ;
Horváth, C .
JOURNAL OF CHROMATOGRAPHY A, 1999, 855 (01) :273-290
[6]   HIGH-PERFORMANCE ELECTROPHORESIS - ELIMINATION OF ELECTROENDOSMOSIS AND SOLUTE ADSORPTION [J].
HJERTEN, S .
JOURNAL OF CHROMATOGRAPHY, 1985, 347 (02) :191-198
[7]   Capillary zone electrophoresis with fluid-impervious polymer tubing inside a fused-silica capillary [J].
Huang, X ;
Horvath, C .
JOURNAL OF CHROMATOGRAPHY A, 1997, 788 (1-2) :155-164
[8]   Surface-alkylated polystyrene monolithic columns for peptide analysis in capillary liquid chromatography-electrospray ionization mass spectrometry [J].
Huang, XA ;
Zhang, S ;
Schultz, GA ;
Henion, J .
ANALYTICAL CHEMISTRY, 2002, 74 (10) :2336-2344
[9]   THE STRUCTURE OF AN AMINOSILANE COUPLING AGENT IN AQUEOUS-SOLUTIONS AND PARTIALLY CURED SOLIDS [J].
ISHIDA, H ;
NAVIROJ, S ;
TRIPATHY, SK ;
FITZGERALD, JJ ;
KOENIG, JL .
JOURNAL OF POLYMER SCIENCE PART B-POLYMER PHYSICS, 1982, 20 (04) :701-718
[10]   Three-dimensional photopatterning of hydrogels containing living cells [J].
Liu, VA ;
Bhatia, SN .
BIOMEDICAL MICRODEVICES, 2002, 4 (04) :257-266