High precision measurements of atmospheric nitrous oxide and methane using thermoelectrically cooled mid-infrared quantum cascade lasers and detectors

被引:176
作者
Nelson, DD
McManus, B
Urbanski, S
Herndon, S
Zahniser, MS
机构
[1] Aerodyne Res Inc, Billerica, MA 10821 USA
[2] Harvard Univ, Dept Earth & Planetary Sci, Cambridge, MA 02138 USA
关键词
quantum cascade lasers; nitrous oxide; methane; infrared absorption;
D O I
10.1016/j.saa.2004.01.033
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A compact, fast response, mid-infrared absorption spectrometer using thermoelectrically (TE) cooled pulsed quantum cascade (QC) lasers and TE detectors has been developed to demonstrate the applicability of QC lasers for high precision measurements of nitrous oxide and methane in the earth's atmosphere. Reduced pressure extractive sampling with a 56 m path length, 0.51 volume, multiple pass absorption cell allows a time response of <0.1 s which is suitable for eddy correlation flux measurements for these gases. Precision of 0.3 ppb (rms, 1 s averaging time) or 0.1% of the ambient concentration for N2O (4 ppb or 0.2% of ambient for CH4), has been demonstrated using QC lasers at 4.5 mum (7.9 mum for CH4), corresponding to an absorbance precision of 4 x 10(-5) Hz(-1/2) (8 x 10(-5) Hz(-1/2) for CH4). Stabilization of the temperature of the optical bench and the pulse electronics results in a minimum Allan variance corresponding to 0.06 ppb for N2O with an averaging time of 100 s (0.7 ppb with an averaging time of 200 s for CH4). The instrument is capable of long-term, unattended, continuous operation without cryogenic cooling of either laser or detector. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:3325 / 3335
页数:11
相关论文
共 20 条
[1]   STATISTICS OF ATOMIC FREQUENCY STANDARDS [J].
ALLAN, DW .
PROCEEDINGS OF THE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS, 1966, 54 (02) :221-&
[2]  
[Anonymous], [No title captured]
[3]  
[Anonymous], 2001, Climate Change 2001:Impacts, Adaptation and Vulnerability
[4]  
[Anonymous], 1986, NUMERICAL RECIPES C
[5]   EDDY-CORRELATION MEASUREMENTS OF METHANE FLUXES USING A TUNABLE DIODE-LASER AT THE KINOSHEO LAKE TOWER SITE DURING THE NORTHERN WETLANDS STUDY (NOWES) [J].
EDWARDS, GC ;
NEUMANN, HH ;
DENHARTOG, G ;
THURTELL, GW ;
KIDD, G .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1994, 99 (D1) :1511-1517
[6]   Global warming in the twenty-first century: An alternative scenario [J].
Hansen, J ;
Sato, M ;
Ruedy, R ;
Lacis, A ;
Oinas, V .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2000, 97 (18) :9875-9880
[7]  
Jimenez J. L., 2000, CHEMOSPHERE GLOBAL C, V2, P397, DOI [DOI 10.1016/S1465-9972(00)00019-2, 10.1016/S1465-9972(00)00019-2]
[8]   Eddy flux measurements of methane over the fen "Murnauer Moos", 11°11′E, 47°39′N, using a fast tunable diode laser spectrometer [J].
Kormann, R ;
Müller, H ;
Werle, P .
ATMOSPHERIC ENVIRONMENT, 2001, 35 (14) :2533-2544
[9]   Trace-gas detection in ambient air with a thermoelectrically cooled, pulsed quantum-cascade distributed feedback laser [J].
Kosterev, AA ;
Tittel, FK ;
Gmachl, C ;
Capasso, F ;
Sivco, DL ;
Baillargeon, JN ;
Hutchinson, AL ;
Cho, AY .
APPLIED OPTICS, 2000, 39 (36) :6866-6872
[10]   Transportable automated ammonia sensor based on a pulsed thermoelectrically cooled quantum-cascade distributed feedback laser [J].
Kosterev, AA ;
Curl, RF ;
Tittel, FK ;
Köhler, R ;
Gmachl, C ;
Capasso, F ;
Sivco, DL ;
Cho, AY .
APPLIED OPTICS, 2002, 41 (03) :573-578