机构:Shanghai Univ, Sch Environm & Chem Engn, Inst Environm Pollut & Hlth, Shanghai 200072, Peoples R China
Wen, Sheng
Lu, Huixiong
论文数: 0引用数: 0
h-index: 0
机构:Shanghai Univ, Sch Environm & Chem Engn, Inst Environm Pollut & Hlth, Shanghai 200072, Peoples R China
Lu, Huixiong
Yu, Zhiqiang
论文数: 0引用数: 0
h-index: 0
机构:Shanghai Univ, Sch Environm & Chem Engn, Inst Environm Pollut & Hlth, Shanghai 200072, Peoples R China
Yu, Zhiqiang
Zhang, Wenbing
论文数: 0引用数: 0
h-index: 0
机构:Shanghai Univ, Sch Environm & Chem Engn, Inst Environm Pollut & Hlth, Shanghai 200072, Peoples R China
Zhang, Wenbing
Sheng, Guoying
论文数: 0引用数: 0
h-index: 0
机构:Shanghai Univ, Sch Environm & Chem Engn, Inst Environm Pollut & Hlth, Shanghai 200072, Peoples R China
Sheng, Guoying
Fu, Jiamo
论文数: 0引用数: 0
h-index: 0
机构:Shanghai Univ, Sch Environm & Chem Engn, Inst Environm Pollut & Hlth, Shanghai 200072, Peoples R China
Fu, Jiamo
机构:
[1] Shanghai Univ, Sch Environm & Chem Engn, Inst Environm Pollut & Hlth, Shanghai 200072, Peoples R China
[2] Chinese Acad Sci, Guangzhou Inst Geochem, Guangzhou Key Lab Environm Protect & Resources Ut, State Key Lab Organ Geochem, Guangzhou 510640, Peoples R China
[3] Chinese Acad Sci, Grad Sch, Beijing 100049, Peoples R China
A method of determination of 32 carbonyl compounds by high performance liquid chromatography (HPLC) and electrospray ionization (ESI) tandem mass spectrometry (MS/MS) after derivatization with 2,4-dinitrophenylhydrazine (DNPH) was developed and successfully applied to the atmosphere sample of a residential area of Liwan District (S1) and a research institute of Tianhe District (S2) in Guangzhou, China. Some operation conditions of ESI-MS/MS in the negative ion mode including selection of parent and daughter ions, declustering potential (DP), entrance potential (EP), collision energy (CE), collision cell exit potential (CXP) and effect of buffer in ESI-MS/MS process were optimized. The regression coefficient of the calibration curves (R-2), recovery, reproducibility (R.S.D., n = 5) and limit of detection (LOD) were in the range of 0.9938-0.9999, 90-104%, 1.7-11 % and 0.4-9.4 ng/m(3) respectively. Among most of the samples, acetone was the most abundant carbonyl in two sampling sites and formaldehyde, acetaldehyde and butyral dehyde/2-butan one were also abundant carbonyls. In contrast to LC-UV method, the LOD, the separation of some co-eluting compounds and the precision (mainly to higher molecular weight carbonyls) are all improved by LC-ESI-MS/MS. (c) 2006 Elsevier B.V. All rights reserved.