Effect of superparamagnetic iron oxide on bone marrow

被引:12
作者
Hundt, W
Petsch, R
Helmberger, T
Reiser, M
机构
[1] Univ Munich, Klinikum Grosshadern, Dept Diagnost Radiol, D-81377 Munich, Germany
[2] Siemens Med Tech, Dept MRI, Erlangen, Germany
关键词
contrast enhancement; contrast media; iron; liver; MR imaging; bone marrow;
D O I
10.1007/s003300000350
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The goal of this study was to compare the effects of SPIO particles on the signal intensity of the bone marrow of the vertebra spine in patients th and without liver cirrhosis. Forty-eight patients lih normal liver tissue and 56 patients with liver cirrhosis were examined before and after intravenous SPIO administration, using a 1.5-T system (Magnetom Vision, Siemens, Erlangen, Germany) with a semiflexible cp-array coil, Three different pulse sequences were applied: a T1-weighted gradient-echo sequence, a T2-weighted East spin-echo sequence spectral fat suppression and a T2*-weighted grant-echo sequence. The signal-to-noise ratio (SNR) the liver, vertebra bone and paraspinal muscle were obtained. The SNR value change in each patient group and the SNR value difference between the two groups were evaluated. For assessment of statistical significance, Student's t-test with a level of p < 0.05 mas applied. No significant differences in the SNR values of the liver and bone marrow between the two groups could be seen with any of the three sequences precontrast. Using the T1-weighted gradient-echo sequence in the noncirrhotic liver group, pre- and postcontrast comparisons of the SNR values be liver and bone marrow indicated a decrease of approximately -44.3% (p = 0.02) and increase of approximately 15.3 % (p = 0.04), respectively. No significant change was seen in the cirrhotic liver group. the T2-weighted fast spin-echo sequence, a significant decrease of the SNR value of the liver and the bone marrow in both groups was seen. With the T2*-weighted gradient-echo sequence, the signal intensity decrease of the normal liver tissue was approximately -65.6 % (p = 0.00), in cirrhotic liver tissue decrease was -29.9 % (p = 0.02). The SNR I of the bone marrow showed a decrease of 27.8% (p = 0.04) in the noncirrhotic liver group, whereas in the cirrhotic liver group it was only 11.3% and statistically not significant. The effect of SPIO particles on the liver and bone marrow is significantly less in patients with liver cirrhosis.
引用
收藏
页码:1495 / 1500
页数:6
相关论文
共 28 条
[1]  
[Anonymous], 1964, LIVER PORTAL HYPERTE
[2]   MORPHOLOGY OF CIRRHOSIS [J].
ANTHONY, PP ;
ISHAK, KG ;
NAYAK, NC ;
POULSEN, HE ;
SCHEUER, PJ ;
SOBIN, LH .
JOURNAL OF CLINICAL PATHOLOGY, 1978, 31 (05) :395-414
[3]   CLINICAL-SIGNIFICANCE OF THE EVALUATION OF HEPATIC RETICULOENDOTHELIAL REMOVAL CAPACITY IN PATIENTS WITH CIRRHOSIS [J].
BOLOGNESI, M ;
MERKEL, C ;
BIANCO, S ;
ANGELI, P ;
SACERDOTI, D ;
AMODIO, P ;
GATTA, A .
HEPATOLOGY, 1994, 19 (03) :628-634
[4]   LIVER-TUMORS IN CIRRHOSIS - EXPERIMENTAL-STUDY WITH SPIO-ENHANCED MR IMAGING [J].
CLEMENT, O ;
FRIJA, G ;
CHAMBON, C ;
SCHOUMANCLAYES, E ;
MOSNIER, JF ;
POUPON, MF ;
BALKAU, B .
RADIOLOGY, 1991, 180 (01) :31-36
[5]   ENDOCYTOSIS, TRANSFER TUBULES, AND LYSOSOMAL ACTIVITY IN MYELOID SINUSOIDAL ENDOTHELIUM [J].
DEBRUYN, PPH ;
MICHELSON, S ;
BECKER, RP .
JOURNAL OF ULTRASTRUCTURE RESEARCH, 1975, 53 (02) :133-151
[6]   HEPATIC CIRRHOSIS AND HEPATITIS - MR IMAGING ENHANCED WITH SUPERPARAMAGNETIC IRON-OXIDE [J].
ELIZONDO, G ;
WEISSLEDER, R ;
STARK, DD ;
GUERRA, J ;
GARZA, J ;
FRETZ, CJ ;
TODD, LE ;
FERRUCCI, JT .
RADIOLOGY, 1990, 174 (03) :797-801
[7]   IRON-OXIDE ENHANCED MR-IMAGING OF THE LIVER AND SPLEEN - REVIEW OF THE 1ST-5 YEARS [J].
FERRUCCI, JT ;
STARK, DD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (05) :943-950
[8]   SUPERPARAMAGNETIC IRON OXIDE-ENHANCED MR IMAGING - PULSE SEQUENCE OPTIMIZATION FOR DETECTION OF LIVER-CANCER [J].
FRETZ, CJ ;
ELIZONDO, G ;
WEISSLEDER, R ;
HAHN, PF ;
STARK, DD ;
FERRUCCI, JT .
RADIOLOGY, 1989, 172 (02) :393-397
[9]   DETECTION OF HEPATIC METASTASES - COMPARISON OF CONTRAST-ENHANCED CT, UNENHANCED MR IMAGING, AND IRON-OXIDE ENHANCED MR IMAGING [J].
FRETZ, CJ ;
STARK, DD ;
METZ, CE ;
ELIZONDO, G ;
WEISSLEDER, R ;
SHEN, JH ;
WITTENBERG, J ;
SIMEONE, J ;
FERRUCCI, JT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (04) :763-770
[10]   SUPERPARAMAGNETIC IRON-OXIDE - CLINICAL TIME-RESPONSE STUDY [J].
GANDON, Y ;
HEAUTOT, JF ;
BRUNET, F ;
GUYADER, D ;
DEUGNIER, Y ;
CARSIN, M .
EUROPEAN JOURNAL OF RADIOLOGY, 1991, 12 (03) :195-200