Determination of bisphenol A in human serum by high-performance liquid chromatography with multi-electrode electrochemical detection

被引:204
作者
Inoue, K
Kato, K
Yoshimura, Y
Makino, T
Nakazawa, H
机构
[1] Hoshi Univ, Fac Pharmaceut Sci, Dept Analyt Chem, Shinagawa Ku, Tokyo 142, Japan
[2] Tokai Univ, Sch Med, Dept Obstet & Gynaecol, Isehara, Kanagawa 251193, Japan
来源
JOURNAL OF CHROMATOGRAPHY B | 2000年 / 749卷 / 01期
关键词
bisphenol A;
D O I
10.1016/S0378-4347(00)00351-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple and sensitive method using high-performance liquid chromatography with multi-electrode electrochemical detection (HPLC-ED) including a coulometric array of four electrochemical sensors has been developed for the determination of bisphenol A in water and human serum. For good separation and detection of bisphenol A, a CAPCELL PAK UG 120 C-18 reversed-phase column and a mobile phase consisting of 0.3% phosphoric acid-acetonitrile (60:40) were used. The detection Limit obtained by the HPLC-ED method was 0.01 ng/ml (0.5 pg), which was more than 3000-times higher than the detection limit obtained by the ultraviolet (UV) method, and more than 200-times higher than the detection limit obtained by the fluorescence (FL) method. Bisphenol A in water and serum samples was pretreated by solid-phase extraction (SPE) after removing possible contamination derived from a plastic SPE cartridges and water used for the pretreatment. A trace amount (ND similar to0.013 ng/ml) of bisphenol A was detected from the parts of cartridges (filtration column, sorbent bed and frits) by extraction with methanol, and it was completely removed by washing with at least 15 mi of methanol in the operation process. The concentrations of bisphenol A in tap water and Milli-Q-purified water were found to be 0.01 and 0.02 ng/ml, respectively. For that reason, bisphenol A-free water was made to trap bisphenol A in water using an Empore disk. In every pretreatment, SPE methods using bisphenol A-free water and washing with 15 mi of methanol were done in water and serum samples. The yields obtained from the recovery tests using water to which 0.5 or 0.05 ng/ml of bisphenol A was added were 83.8 to 98.2%, and the RSDs were 3.4 to 6.1%, respectively. The yields obtained from the recovery tests by OASIS HLB using serum to which 1.0 ng/ml or 0.1 ng/ml of bisphenol A was added were 79.0% and 87.3%, and the RSDs were 5.1% and 13.5%, respectively. The limits of quantification in water and serum sample were 0.01 ng/ml and 0.05 ng/ml, respectively. The method was applied to the determination of bisphenol A in healthy human serum sample, and the obtained detection was 0.32 ng/ml. From these results, the HPLC-ED method should be the most useful in the determination of bisphenol A at low concentration levels in water and biological samples. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:17 / 23
页数:7
相关论文
共 25 条
[1]   SIMULTANEOUS DETERMINATION OF 27 PHENOLS AND HERBICIDES IN WATER BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH MULTIELECTRODE ELECTROCHEMICAL DETECTION [J].
ACHILLI, G ;
CELLERINO, GP ;
DERIL, GM ;
BIRD, S .
JOURNAL OF CHROMATOGRAPHY A, 1995, 697 (1-2) :357-362
[2]   Solid-phase extraction for the determination of tricyclic antidepressants in serum using a novel polymeric extraction sorbent [J].
Cheng, YF ;
Phillips, DJ ;
Neue, U ;
Bean, L .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1997, 20 (15) :2461-2473
[3]   Simple and rugged SPE method for the determination of tetracycline antibiotics in serum by HPLC using a volatile mobile phase [J].
Cheng, YF ;
Phillips, DJ ;
Neue, U .
CHROMATOGRAPHIA, 1997, 44 (3-4) :187-190
[4]  
CHENG YF, 1997, AM BIOTECH DEC, P14
[5]   Trace determination of phenol, bisphenol A and bisphenol A diglycidyl ether in mixtures by excitation fluorescence following micro liquid-liquid extraction using partial least squares regression [J].
del Olmo, M ;
Zafra, A ;
Navas, NA ;
Vílchez, JL .
ANALYST, 1999, 124 (03) :385-390
[6]   Determination of bisphenol A (BPA) in water by gas chromatography mass spectrometry [J].
delOlmo, M ;
GonzalezCasado, A ;
Navas, NA ;
Vilchez, JL .
ANALYTICA CHIMICA ACTA, 1997, 346 (01) :87-92
[7]   Evaluation of chemicals with endocrine modulating activity in a yeast-based steroid hormone receptor gene transcription assay [J].
Gaido, KW ;
Leonard, LS ;
Lovell, S ;
Gould, JC ;
Babai, D ;
Portier, CJ ;
McDonnell, DP .
TOXICOLOGY AND APPLIED PHARMACOLOGY, 1997, 143 (01) :205-212
[8]   Determination of bisphenol A in water by micro liquid-liquid extraction followed by silylation and gas chromatography mass spectrometry analysis [J].
González-Casado, A ;
Navas, N ;
del Olmo, M ;
Vílchez, JL .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1998, 36 (11) :565-569
[9]  
GONZALEZCASADO A, 1996, J CHROMATOGR A, V726, P133
[10]   Pesticide monitoring of drinking water with the help of solid-phase extraction and high-performance liquid chromatography [J].
JunkerBuchheit, A ;
Witzenbacher, M .
JOURNAL OF CHROMATOGRAPHY A, 1996, 737 (01) :67-74