Purpose: We investigated the relationship between the amount of radiation exposure to the operator during table-side manual-injection angiographic procedures including digital subtraction angiography (DSA) and the operator's position, as well as a simple means to decrease radiation exposure. Methods: Measurement of radiation exposure was carried out with thermoluminescent dosimeters (TLDs) in nine abdominal angiographies. In the first study, radiation exposure during DSA or during fluoroscopy was measured using TLDs placed near the angiographic table. In the second study, radiation exposure to the interventional radiologist was measured during manual-injection DA at a near and a far operator position. Results: Radiation exposure to the operator received during manual-injection DSA accounted for more than 90% of the total procedural exposure. The exposure to the operator markedly decreased at: the far position compared with that at the near position when performing DSA. Conclusion: Manual-injection DSA is the largest contributor to radiation exposure received by the interventional radiologist, therefore, the use of a power injector is always recommended when performing DSA. When manual-injection DSA is necessary, radiologists should position themselves as far away from the patient as possible.
引用
收藏
页码:240 / 243
页数:4
相关论文
共 10 条
[1]   RADIATION EXPOSURE TO OPERATOR PERFORMING CARDIAC ANGIOGRAPHY WITH U-ARM SYSTEMS [J].
BALTER, S ;
SONES, FM ;
BRANCATO, R .
CIRCULATION, 1978, 58 (05) :925-932
[2]  
BERTHELSEN B, 1991, ACTA RADIOL, V32, P492
[3]   RADIATION EXPOSURE DURING RADIOFREQUENCY CATHETER ABLATION OF ACCESSORY ATRIOVENTRICULAR CONNECTIONS [J].
CALKINS, H ;
NIKLASON, L ;
SOUSA, J ;
ELATASSI, R ;
LANGBERG, J ;
MORADY, F .
CIRCULATION, 1991, 84 (06) :2376-2382
[4]   RADIATION EXPOSURE TO PATIENTS UNDERGOING PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY [J].
CASCADE, PN ;
PETERSON, LE ;
WAJSZCZUK, WJ ;
MANTEL, J .
AMERICAN JOURNAL OF CARDIOLOGY, 1987, 59 (09) :996-997
[5]   CLINICAL DOSIMETRY DURING CEREBRAL ARTERIOGRAPHY [J].
CHOPP, M ;
PORTNOY, HD ;
SCHURIG, R ;
CROISSANT, P .
NEURORADIOLOGY, 1980, 20 (02) :79-81
[6]  
JUDKINS MP, 1984, CATHETER CARDIO DIAG, V10, P87
[7]  
NCRP, 1990, Implementation of the principle of as low as reasonably achievable (ALARA) for medical and dental personnel
[8]   EXPOSURE OF RADIOLOGISTS DURING SPECIAL PROCEDURES [J].
RILEY, RC ;
TEMPLETO.AW ;
BIRKS, JW ;
PALACIOS, E .
RADIOLOGY, 1972, 104 (03) :679-&
[9]   THE RADIOLOGIST AND ANGIOGRAPHIC PROCEDURES - ABSORBED RADIATION-DOSE [J].
TRYHUS, M ;
METTLER, FA ;
KELSEY, C .
INVESTIGATIVE RADIOLOGY, 1987, 22 (09) :747-750
[10]   POTENTIAL BIOLOGICAL EFFECTS FOLLOWING HIGH X-RAY DOSE INTERVENTIONAL PROCEDURES [J].
WAGNER, LK ;
EIFEL, PJ ;
GEISE, RA .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1994, 5 (01) :71-84