Real-time precision concentration measurement for flowing liquid solutions

被引:31
作者
Krishna, V [1 ]
Fan, CH [1 ]
Longtin, JP [1 ]
机构
[1] SUNY Stony Brook, Dept Mech Engn, Stony Brook, NY 11794 USA
关键词
D O I
10.1063/1.1288236
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The precise, real-time measurement of liquid concentration is important in fundamental research, chemical analysis, mixing processes, and manufacturing, e.g., in the food and semiconductor industries. This work presents a laser-based, noninvasive technique to measure concentration changes of flowing liquids in real time. The essential components in the system include a 5 mW laser diode coupled to a single-mode optical fiber, a triangular optical cell, and a high-resolution beam position sensor. The instrument provides a large range of concentration measurement, typically 0%-100% for binary liquid mixtures, while providing a resolution on the order of 0.05% concentration or better. The experimental configuration is small, reliable, and inexpensive. Results are presented for NaCl and MgCl2 aqueous solutions with concentrations ranging from 0% to 25%, with very good agreement found between measured and true concentrations. (C) 2000 American Institute of Physics. [S0034-6748(00)00410-X].
引用
收藏
页码:3864 / 3868
页数:5
相关论文
共 18 条
[1]   MINIATURE FIBER-OPTIC REFRACTOMETER FOR MEASUREMENT OF SALINITY IN DOUBLE-DIFFUSIVE THERMOHALINE SYSTEMS [J].
BERGMAN, TL ;
INCROPERA, FP ;
STEVENSON, WH .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1985, 56 (02) :291-296
[2]   MEASUREMENT OF SALINITY DISTRIBUTIONS IN SALT-STRATIFIED, DOUBLE-DIFFUSIVE SYSTEMS BY OPTICAL DEFLECTOMETRY [J].
BERGMAN, TL ;
MUNOZ, DR ;
INCROPERA, FP ;
VISKANTA, R .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1986, 57 (10) :2538-2542
[3]   A new technique for measuring the Fickian diffusion coefficient in binary liquid solutions [J].
Capobianchi, M ;
Irvine, TF ;
Tutu, NK ;
Greene, GA .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1998, 18 (01) :33-47
[4]  
GEAKE JE, 1975, CHEM ENG-LONDON, P305
[5]   OPTICAL-CONSTANTS OF WATER IN 200-NM TO 200-MUM WAVELENGTH REGION [J].
HALE, GM ;
QUERRY, MR .
APPLIED OPTICS, 1973, 12 (03) :555-563
[6]   INFRARED THERMO-OPTIC COEFFICIENT MEASUREMENT OF POLYCRYSTALLINE ZNSE, ZNS, CDTE, CAF2, AND BAF2, SINGLE-CRYSTAL KCL, AND TL-20 GLASS [J].
HARRIS, RJ ;
JOHNSTON, GT ;
KEPPLE, GA ;
KROK, PC ;
MUKAI, H .
APPLIED OPTICS, 1977, 16 (02) :436-438
[7]   Micro-electro-mechanical-systems (MEMS) and fluid flows [J].
Ho, CM ;
Tai, YC .
ANNUAL REVIEW OF FLUID MECHANICS, 1998, 30 :579-612
[8]   Ultrasonic measurement of concentration in solutions by a phase-locked loop method [J].
Ikeda, K .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1997, 36 (5B) :3180-3183
[9]   Transient two-dimensional fuel-concentration measurement technique [J].
Konishi, T ;
Naka, S ;
Ito, A ;
Saito, K .
APPLIED OPTICS, 1997, 36 (33) :8815-8819
[10]  
LIDE DR, 1998, CRC HDB CHEM PHYSICS