Determination of optimum air-layer thickness in double-pane windows

被引:65
作者
Aydin, O [1 ]
机构
[1] Karadeniz Tech Univ, Dept Engn Mech, TR-61080 Trabzon, Turkey
关键词
low-energy buildings; double-pane windows; optimum air-layer thickness; numerical simulation;
D O I
10.1016/S0378-7788(00)00057-8
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study, heat transfer through a double-pane window is numerically analyzed by a finite difference technique. The aim of the study is to determine the thermally optimum air-layer thickness between the two panes for different climates. Four different cities of Turkey, representing different climate conditions are considered: Ankara, Antalya, Kars and Trabzon. The height of the window, H is chosen 80 cm. The effect of air-layer thickness varies between 3 and 40 mm on the average Nusselt number and the heat flux through the inner pane. It was shown that energy losses through the double-pane windows can be considerably reduced by optimizing the thickness of air layer. (C) 2000 Published by Elsevier Science S.A.
引用
收藏
页码:303 / 308
页数:6
相关论文
共 13 条
[1]   Free convection analysis of a window cavity and its longitudinal temperature profile [J].
Abodahab, N ;
Muneer, T .
ENERGY CONVERSION AND MANAGEMENT, 1998, 39 (3-4) :257-267
[2]   Natural convection in rectangular enclosures heated from one side and cooled from the ceiling [J].
Aydin, O ;
Ünal, A ;
Ayhan, T .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1999, 42 (13) :2345-2355
[3]  
DAVIS GD, 1983, INT J NUMER METH FL, V3, P249
[4]   Environmental conditions in window frames with double-glazing units [J].
Garvin, SL ;
Wilson, J .
CONSTRUCTION AND BUILDING MATERIALS, 1998, 12 (05) :289-302
[5]   HEAT-TRANSFER THROUGH A DOUBLE PANE WINDOW [J].
KORPELA, SA ;
LEE, Y ;
DRUMMOND, JE .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1982, 104 (03) :539-544
[6]   MULTICELLULAR NATURAL-CONVECTION IN A VERTICAL SLOT [J].
LEE, Y ;
KORPELA, SA .
JOURNAL OF FLUID MECHANICS, 1983, 126 (JAN) :91-121
[7]   Heat transfer through a double pane window with an insulation screen open at the top [J].
Medved, S ;
Novak, P .
ENERGY AND BUILDINGS, 1998, 28 (03) :257-268
[8]   Frequency of condensation occurrence on double-glazing in the United Kingdom [J].
Muneer, T ;
Abodahab, N .
ENERGY CONVERSION AND MANAGEMENT, 1998, 39 (08) :717-726
[9]   Simplified analysis for free convection in enclosures - Application to an industrial problem [J].
Muneer, T ;
Han, B .
ENERGY CONVERSION AND MANAGEMENT, 1996, 37 (09) :1463-1467
[10]   NATURAL-CONVECTION HEAT-TRANSFER IN SLENDER WINDOW CAVITIES [J].
NOVAK, MH ;
NOWAK, ES .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1993, 115 (02) :476-479