Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization

被引:230
作者
Bacher, K
Bogaert, E
Lapere, R
De Wolf, D
Thierens, H
机构
[1] Univ Ghent, Dept Med Phys & Radiat Protect, B-9000 Ghent, Belgium
[2] Ghent Univ Hosp, Dept Pediat Cardiol, B-9000 Ghent, Belgium
关键词
catheterization; pediatrics; radiation;
D O I
10.1161/01.CIR.0000151098.52656.3A
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - Because of the higher radiosensitivity of infants and children compared with adults, there is a need to evaluate the doses delivered to pediatric patients who undergo interventional cardiac procedures. However, knowledge of the effective dose in pediatric interventional cardiology is very limited. Methods and Results - For an accurate risk estimation, a patient-specific Monte Carlo simulation of the effective dose was set up in 60 patients with congenital heart disease who underwent diagnostic (n=28) or therapeutic (n=32) cardiac catheterization procedures. The dose-saving effect of using extra copper filtration in the x-ray beam was also investigated. For diagnostic cardiac catheterizations, a median effective dose of 4.6 mSv was found. Therapeutic procedures resulted in a higher median effective dose of 6.0 mSv because of the prolonged use of fluoroscopy. The overall effect of inserting extra copper filtration into the x-ray beam was a total effective dose reduction of 18% with no detrimental effect on image quality. An excellent correlation between the dose-area product and effective patient dose was found (r=0.95). Hence, dose-area product is suitable for online estimation of the effective dose with good accuracy. With all procedures included, the resulting median lifetime risk for stochastic effects was 0.08%. Conclusions - Because of the high radiation exposure, it is important to monitor patient dose by dose-area product instrumentation and to use additional beam filtration to keep the effective dose as low as possible in view of the sensitivity of the pediatric patients.
引用
收藏
页码:83 / 89
页数:7
相关论文
共 30 条
[1]   GUIDELINES FOR PEDIATRIC THERAPEUTIC CARDIAC-CATHETERIZATION - A STATEMENT FOR HEALTH-PROFESSIONALS FROM THE COMMITTEE ON CONGENITAL CARDIAC DEFECTS OF THE COUNCIL ON CARDIOVASCULAR-DISEASE IN THE YOUNG, THE AMERICAN-HEART-ASSOCIATION [J].
ALLEN, HD ;
DRISCOLL, DJ ;
FRICKER, FJ ;
HERNDON, P ;
MULLINS, CE ;
SNIDER, AR ;
TAUBERT, KA .
CIRCULATION, 1991, 84 (05) :2248-2258
[2]   Estimating the effective dose to children undergoing heart investigations - a phantom study [J].
Axelsson, B ;
Khalil, C ;
Lidegran, M ;
Schuwert, P ;
Mortensson, W .
BRITISH JOURNAL OF RADIOLOGY, 1999, 72 (856) :378-383
[3]  
Bakalyar DM, 1997, CATHETER CARDIO DIAG, V42, P121, DOI 10.1002/(SICI)1097-0304(199710)42:2<121::AID-CCD4>3.3.CO
[4]  
2-Y
[5]  
Baldazzi G, 2002, PHYS MEDICA, V18, P109
[6]   Radiation exposure to children during cardiac catheterization [J].
Boothroyd, A ;
McDonald, E ;
Moores, BM ;
Sluming, V ;
Carty, H .
BRITISH JOURNAL OF RADIOLOGY, 1997, 70 :180-185
[7]  
Briesmeister J.F, 1997, MCNP GEN MONTE CARLO
[8]  
CHRISTY M, 1987, ORNLTM8381
[9]   Real-time quantification and display of skin radiation during coronary angiography and intervention [J].
den Boer, A ;
de Feijter, PJ ;
Serruys, PW ;
Roelandt, JRTC .
CIRCULATION, 2001, 104 (15) :1779-1784
[10]   Comparison of four techniques to estimate radiation dose to skin during angiographic and interventional radiology procedures [J].
Fletcher, DW ;
Miller, DL ;
Balter, S ;
Taylor, MA .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (04) :391-397