Computerized scheme for determination of the likelihood measure of malignancy for pulmonary nodules on low-dose CT images

被引:96
作者
Aoyama, M [1 ]
Li, Q [1 ]
Katsuragawa, S [1 ]
Li, F [1 ]
Sone, S [1 ]
Doi, K [1 ]
机构
[1] Univ Chicago, Dept Radiol, Kurt Rossmann Labs Radiol Image Res, Chicago, IL 60637 USA
关键词
automated computerized scheme; dynamic programming; image features; linear discriminant analysis; receiver operating characteristic analysis;
D O I
10.1118/1.1543575
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An automated computerized scheme has been developed for determination of the likelihood measure of malignancy of pulmonary nodules on low-dose helical CT (LDCT) images. Our database consisted of 76 primary lung cancers (147 slices) and 413 benign nodules (576 slices). With this automated computerized scheme, the location of a nodule was first indicated by a radiologist. The outline of the nodule was segmented automatically by use of a dynamic programming technique. Various objective features on the nodules were determined by use of outline analysis and image analysis, and the likelihood measure of malignancy was determined by use of linear discriminant analysis (LDA). The effect of many different combinations of features and the performance of LDA in distinguishing benign nodules from malignant ones were evaluated by means of receiver operating characteristic (ROC) analysis. The Az value (area under the ROC curve) obtained by the computerized scheme in distinguishing benign nodules from malignant ones was 0.828 when a single slice was employed for each of the nodules. However, the Az value was improved to 0.846 when multiple slices were used for determination of the likelihood measure of malignancy. The Az values obtained by the computerized scheme on LDCT images were significantly greater than the Az value of 0.70, which was obtained from our previous observer studies by radiologists in distinguishing benign nodules from malignant ones on LDCT images. The automated computerized scheme for determination of the likelihood measure of malignancy would be useful in assisting radiologists to distinguish between benign and malignant pulmonary nodules on LDCT images. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:387 / 394
页数:8
相关论文
共 29 条
[1]   USING DYNAMIC-PROGRAMMING FOR SOLVING VARIATIONAL-PROBLEMS IN VISION [J].
AMINI, AA ;
WEYMOUTH, TE ;
JAIN, RC .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1990, 12 (09) :855-867
[2]   Automated computerized scheme for distinction between benign and malignant solitary pulmonary nodules on chest images [J].
Aoyama, M ;
Li, Q ;
Katsuragawa, S ;
MacMahon, H ;
Doi, K .
MEDICAL PHYSICS, 2002, 29 (05) :701-708
[3]  
BICK U, 1995, P CAR 95, P357
[4]  
Fitzgibbon A. W., 1996, Proceedings of the 13th International Conference on Pattern Recognition, P253, DOI 10.1109/ICPR.1996.546029
[5]   CT screening for lung cancer [J].
Henschke, CI ;
Yankelevitz, DF .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2000, 38 (03) :487-+
[6]   ANALYSIS OF SPICULATION IN THE COMPUTERIZED CLASSIFICATION OF MAMMOGRAPHIC MASSES [J].
HUO, ZM ;
GIGER, ML ;
VYBORNY, CJ ;
BICK, U ;
LU, P ;
WOLVERTON, DE ;
SCHMIDT, RA .
MEDICAL PHYSICS, 1995, 22 (10) :1569-1579
[7]   Computerized analysis of interstitial disease in chest radiographs: Improvement of geometric-pattern feature analysis [J].
Ishida, T ;
Katsuragawa, S ;
Kobayashi, T ;
MacMahon, H ;
Doi, K .
MEDICAL PHYSICS, 1997, 24 (06) :915-924
[8]   Malignant and benign clustered microcalcifications: Automated feature analysis and classification [J].
Jiang, YL ;
Nishikawa, RM ;
Wolverton, DE ;
Metz, CE ;
Giger, ML ;
Schmidt, RA ;
Vyborny, CJ ;
Doi, K .
RADIOLOGY, 1996, 198 (03) :671-678
[9]  
JOHNSON RA, 1992, APPL MULTIVARIATE ST, P184
[10]   IMAGE FEATURE ANALYSIS AND COMPUTER-AIDED DIAGNOSIS IN DIGITAL RADIOGRAPHY - EFFECT OF DIGITAL PARAMETERS ON THE ACCURACY OF COMPUTERIZED ANALYSIS OF INTERSTITIAL DISEASE IN DIGITAL CHEST RADIOGRAPHS [J].
KATSURAGAWA, S ;
DOI, K ;
NAKAMORI, N ;
MACMAHON, H .
MEDICAL PHYSICS, 1990, 17 (01) :72-78