High incidence of thrombus formation without impedance rise during radiofrequency ablation using electrode temperature control

被引:69
作者
Matsudaira, K
Nakagawa, H
Wittkampf, FHM
Yamanashi, WS
Imai, S
Pitha, JV
Lazzara, R
Jackman, WM
机构
[1] Univ Oklahoma, Cardiac Arrhythmia Res Inst, Hlth Sci Ctr, Oklahoma City, OK 73104 USA
[2] Univ Oklahoma, Dept Med, Hlth Sci Ctr, Oklahoma City, OK 73104 USA
[3] Univ Utrecht, Med Ctr, Utrecht, Netherlands
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2003年 / 26卷 / 05期
关键词
catheter ablation; thrombus; radiofrequency;
D O I
10.1046/j.1460-9592.2003.t01-1-00173.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The authors hypothesized that during RF ablation, the electrode to tissue interface temperature may significantly exceed electrode temperature in the presence of cooling blood flow and produce thrombus. In 12 anesthetized dogs, the skin over the thigh muscle was incised and raised to form a cradle that was superfused with heparinized canine blood (ACT > 350 s) at 37degreesC. A 7 Fr, 4-mm or 8-mm ablation electrode containing a thermocouple was held perpendicular to the thigh muscle at 10-g contact weight. Interface temperature was measured at opposite sides of the electrode using tiny optical probes. RF applications (n = 157) were delivered at an electrode temperature of 45 degreesC, 55 degreesC, 65 degreesC, and 75 degreesC for 60 seconds, with or without pulsatile blood flow (150 mL/min). Without blood flow, the interface temperature was similar to the electrode temperature. With blood flow, the interface temperature (side opposite blood flow) was up to 36 degreesC and 57 degreesC higher than the electrode temperature using the 4- and 8-mm electrodes, respectively. After each RF, the cradle was emptied and the electrode and interface were examined. Thrombus developed without impedance rise at an interface temperature as low as 73 degreesC without blood flow and 80 degreesC with blood flow (11/16 RFs at 65 degreesC electrode temperature using 4 mm and 13/13 RFs at an electrode temperature of 55 degreesC using an 8-mm electrode with blood flow). With blood flow, interface temperature markedly exceeded the electrode temperature and the difference was greater with an 8-mm electrode (due to greater electrode cooling). In the presence of blood flow, thrombus occurred without an impedance rise at an electrode temperature as low as 65 degreesC with a 4-mm electrode and 55 degreesC with an 8-mm electrode.
引用
收藏
页码:1227 / +
页数:12
相关论文
共 24 条
[1]   ASSESSMENT OF EFFECTS OF A RADIOFREQUENCY ENERGY-FIELD AND THERMISTOR LOCATION IN AN ELECTRODE CATHETER ON THE ACCURACY OF TEMPERATURE-MEASUREMENT [J].
BLOUIN, LT ;
MARCUS, FI ;
LAMPE, L .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (05) :807-813
[2]   TEMPERATURE MONITORING DURING RADIOFREQUENCY CATHETER ABLATION PROCEDURES USING CLOSED-LOOP CONTROL [J].
CALKINS, H ;
PRYSTOWSKY, E ;
CARLSON, M ;
KLEIN, LS ;
SAUL, JP ;
KAY, GN ;
DAILEY, S ;
EPSTEIN, A ;
PLUMB, V ;
WHARTON, M ;
KANTER, R ;
SORRENTINO, R ;
GREENFIELD, RA ;
WALSH, E ;
WALDO, A ;
BIBLO, L ;
JOHNSON, N ;
LIEBERMAN, R ;
ROSENBAUM, D ;
HUANG, SKS ;
MITTLEMAN, RS ;
WAGSHAL, AB ;
GREENE, T ;
LIEM, B ;
LAUER, M ;
SUNG, R ;
YOUNG, C ;
EVANS, J ;
CASE, C ;
HACKETT, K ;
MILES, W ;
ZIPES, D ;
LAWRENCE, J ;
TOMASELLI, G ;
BERGER, R .
CIRCULATION, 1994, 90 (03) :1279-1286
[3]  
EICK OJ, 2001, PACE, V24, P659
[4]   Embolic complications associated with radiofrequency catheter ablation [J].
Epstein, MR ;
Knapp, LD ;
Martindill, M ;
Lulu, JA ;
Triedman, JK ;
Calkins, H ;
Huang, SKS ;
Walsh, EP ;
Saul, JP .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (08) :655-+
[5]   Interrelation of tissue temperature versus flow velocity in two different kinds of temperature-controlled catheter radiofrequency energy applications [J].
Gumbrecht, S ;
Neuzner, J ;
Pitschner, HF .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 1998, 2 (02) :211-219
[6]   OBSERVATIONS ON ELECTRODE-TISSUE INTERFACE TEMPERATURE AND EFFECT ON ELECTRICAL-IMPEDANCE DURING RADIOFREQUENCY ABLATION OF VENTRICULAR MYOCARDIUM [J].
HAINES, DE ;
VEROW, AF .
CIRCULATION, 1990, 82 (03) :1034-1038
[7]   CATHETER ABLATION OF ATRIOVENTRICULAR JUNCTION USING RADIOFREQUENCY CURRENT IN 17 PATIENTS - COMPARISON OF STANDARD AND LARGE-TIP CATHETER ELECTRODES [J].
JACKMAN, WM ;
WANG, XZ ;
FRIDAY, KJ ;
FITZGERALD, DM ;
ROMAN, C ;
MOULTON, K ;
MARGOLIS, PD ;
BOWMAN, AJ ;
KUCK, KH ;
NACCARELLI, GV ;
PITHA, JV ;
DYER, J ;
LAZZARA, R .
CIRCULATION, 1991, 83 (05) :1562-1576
[8]   In vitro temperature map of cardiac ablation demonstrates the effect of flow on lesion development [J].
Jain, MK ;
Wolf, PD .
ANNALS OF BIOMEDICAL ENGINEERING, 2000, 28 (09) :1066-1074
[9]  
Jaïs P, 1999, AM J CARDIOL, V84, p139R
[10]  
KAY GN, 2001, PACING CLIN ELECTROP, V24, P608