Preparation of ethambutol-copper(II) complex and fabrication of PVC based membrane potentiometric sensor for copper

被引:232
作者
Gupta, VK [1 ]
Prasad, R [1 ]
Kumar, A [1 ]
机构
[1] Indian Inst Technol Roorkee, Dept Chem, Roorkee 247667, Uttar Pradesh, India
关键词
ethambutol; Cu2+; potentiometric sensor; poly(vinyl chloride); selectivity;
D O I
10.1016/S0039-9140(03)00118-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Copper(II) complex of ethambutol (1) was prepared and used in the fabrication Of Cu2+ selective ISE membrane. The membrane having Cu(II)-ethambutol complex (1) as electroactive material, along with sodium tetraphenylborate (NaTPB) as anion discriminator, dioctylphthalate (DOP) as plasticizer in poly(vinyl chloride) (PVC) matrix in the percentage ratio 6:2-190:200 (I:NaTPB:DOP:PVC) (w/w) gave a linear response in the concentration range 7.94 x 10(-6) to 1.0 X 10(-1) M Of Cu2+ with a slope of 29.9 +/- 0.2 mV per decade of activity and a fast response time of 11 +/- 2 s. The sensor works well in the pH range 2.1-6.3 and could be satisfactorily used in presence of 40% (v/v) methanol, ethanol and acetone and is-selective for copper over a large number of cations with slight interference from Na+ and Co2+ if present at a level greater than or equal to 1.5 x 10(-5) and 6.5 x 10(-5) M, respectively. It works well over a period of 6 months and can also be used as indicator electrode for the end point determination in the potentiometric titration of Cu 2+ against EDTA as well as in the determination of Cu2+ in real samples. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:149 / 160
页数:12
相关论文
共 20 条
[1]   Copper(II)-selective membrane electrode based on a recently synthesized naphthol-derivative Schiff's base [J].
Alizadeh, N ;
Ershad, S ;
Naeimi, H ;
Sharghi, H ;
Shamsipur, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 365 (06) :511-515
[2]  
BHATTACHARYYA RG, 1990, INDIAN J CHEM A, V29, P986
[3]   COMPARISONS OF 13-MEMBERED TO 16-MEMBERED TETRA-AZACYCLOALKANE COPPER(II) COMPLEXES DERIVED FROM TEMPLATE SYNTHESES INVOLVING NITROETHANE AND FORMALDEHYDE - CRYSTAL-STRUCTURES OF (10-METHYL-10-NITRO-1,4,8,12-TETRA-AZACYCLOPENTADECANE)COPPER(II) AND (3-METHYL-3-NITRO-1,5,9,13-TETRA-AZACYCLOHEXADECANE)COPPER(II) PERCHLORATESE [J].
COMBA, P ;
CURTIS, NF ;
LAWRANCE, GA ;
OLEARY, MA ;
SKELTON, BW ;
WHITE, AH .
JOURNAL OF THE CHEMICAL SOCIETY-DALTON TRANSACTIONS, 1988, (08) :2145-2152
[4]   DETERMINATION AND APPLICATION OF ION-SELECTIVE ELECTRODE MODEL PARAMETERS USING FLOW-INJECTION AND SIMPLEX OPTIMIZATION [J].
DEVITERI, FJS ;
DIAMOND, D .
ANALYST, 1994, 119 (05) :749-758
[5]  
Dyer J.R., 1987, APPL ABSORPTION SPEC
[6]   DETERMINATION OF SELECTIVITY COEFFICIENTS OF ION-SELECTIVE ELECTRODES BY A MATCHED-POTENTIAL METHOD [J].
GADZEKPO, VPY ;
CHRISTIAN, GD .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :279-282
[7]   Cadmium(II)-selective sensors based on dibenzo-24-crown-8 in PVC matrix [J].
Gupta, VK ;
Kumar, P .
ANALYTICA CHIMICA ACTA, 1999, 389 (1-3) :205-212
[8]   NEUTRAL CARRIER AND ORGANIC RESIN-BASED MEMBRANES AS SENSORS FOR URANYL IONS [J].
JAIN, AK ;
GUPTA, VK ;
SINGH, LP .
ANALYTICAL PROCEEDINGS, 1995, 32 (07) :263-266
[9]   COPPER(II)-SELECTIVE MEMBRANE ELECTRODES BASED ON ORTHO-XYLYLENE BIS(DITHIOCARBAMATES) AS NEUTRAL CARRIERS [J].
KAMATA, S ;
MURATA, H ;
KUBO, Y ;
BHALE, A .
ANALYST, 1989, 114 (09) :1029-1031
[10]   COPPER(II)-SELECTIVE ELECTRODES BASED ON MACROCYCLIC POLYTHIAETHERS [J].
KAMATA, S ;
YAMASAKI, K ;
HIGO, M ;
BHALE, A ;
FUKUNAGA, Y .
ANALYST, 1988, 113 (01) :45-47