Dosage measurement in spiral CT examinations in the head and neck region

被引:11
作者
Cohnen, M
Cohnen, B
Ewen, K
Teubert, G
Modder, U
机构
[1] Univ Dusseldorf, Inst Diagnost Radiol, D-4000 Dusseldorf, Germany
[2] Landesanstalt Arbeitsschutz, Dusseldorf, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 1998年 / 168卷 / 05期
关键词
computed tomography; radiation exposure; conventional CT; spiral CT; dose reduction;
D O I
10.1055/s-2007-1015164
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In view of the increasing frequency of computed tomographic examinations the organ doses of the thyroid gland and the eye lenses in spiral CT examinations of the head and neck should be determined. Material and methods: Standard CT-examinations of the neck, the paranasal sinuses in axial and coronal sections, and the mandibula were simulated by help of an Anderson-Rando phantom. Dose measurements were performed as well in 28 patients. The examinations were carried out in spiral mode ("Somatom AR.SP" "Picker PQ 2000", and "Toshiba Xpress SX") and conventional single slice technique ("Somatom Plus"). Three LiF-TLD were placed on each eyelid and three on the thyroid. Results: With direct exposure to the x-ray-beam the organ doses did not exceed 64 mGy. When exposed by scatter radiation only, doses may be reduced by a factor of up to 10. The measurements in 28 patients showed similar results. Conclusions: The organ doses in spiral CT correspond with data known from conventional CT.
引用
收藏
页码:474 / 479
页数:6
相关论文
共 27 条
[1]  
Beus J, 1995, Aktuelle Radiol, V5, P189
[2]   AVERAGE RADIATION-DOSE IN STANDARD CT EXAMINATIONS OF THE HEAD - RESULTS OF THE 1990 NEXT SURVEY [J].
CONWAY, BJ ;
MCCROHAN, JL ;
ANTONSEN, RG ;
RUETER, FG ;
SLAYTON, RJ ;
SULEIMAN, OH .
RADIOLOGY, 1992, 184 (01) :135-140
[3]   Low-dose spiral-CT [J].
Diederichs, CG ;
Bruhn, H ;
Funke, M ;
Grabbe, E .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1996, 164 (03) :183-188
[4]  
Ewen K, 1980, Rofo, V133, P425, DOI 10.1055/s-2008-1056757
[5]  
Gollnast H K, 1993, Aktuelle Radiol, V3, P20
[6]  
HAGEMANN G, 1992, STRAHLENSCHUTZ FORSC, P143
[7]   RADIATION-DOSE TO THE LENS AND CATARACT FORMATION [J].
HENK, JM ;
WHITELOCKE, RAF ;
WARRINGTON, AP ;
BESSELL, EM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (05) :815-820
[8]  
HESSELINK JR, 1979, RADIOLOGY, V133, P197
[9]  
HIDAJAT N, 1995, RADIOLOGE, V35, pS164
[10]   MEDICAL DIAGNOSTIC X-RAYS AND THYROID-CANCER [J].
INSKIP, PD ;
EKBOM, A ;
GALANTI, MR ;
GRIMELIUS, L ;
BOICE, JD .
JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1995, 87 (21) :1613-1621