Imaging of breast phantoms using a high-resolution position sensitive photomultiplier tube

被引:16
作者
Giokaris, ND
Loudos, GK
Maintas, D
Papapanagiotou, D
Nikita, KS
Uzunoglu, NK
Karabarbounis, A
Papanicolas, CN
Stillaris, E
Archimandritis, SC
Varvarigou, AD
Stefanis, CN
Majewski, S
Weisen-berger, A
Pani, R
Scopinaro, F
机构
[1] Inst Accelerating Syst & Applicat, Athens 10024, Greece
[2] Natl Tech Univ Athens, GR-15773 Athens, Greece
[3] Natl Capodistrian Univ Athens, Athens 10679, Greece
[4] Natl Ctr Sci Res Demokritos, Athens 15310, Greece
[5] Athens Med Ctr, Inst Isotop Studies, Athens 15125, Greece
[6] Univ Athens, Mental Hlth Res Inst, Athens 11521, Greece
[7] Jefferson Lab, Newport News, VA USA
[8] Univ Roma La Sapienza, Rome, Italy
关键词
PSPMT; breast phantoms; high resolution; sensitivity; maximum likelihood; hot" spot;
D O I
10.1016/S0168-9002(02)01904-6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The results of studies conducted with a small field of view gamma camera based on a Position Sensitive Photomultiplier Tube (PSPMT) and a pixelized scintillator crystal, made of CsI(TI), are reported. Using a computer-controlled step motor allowing object rotation, projection data from several angles are acquired. Images of slices of the object are obtained and compared with the use of a Filtered Backprojection and a Maximum Likelihood algorithm. Phantom studies have shown a spatial resolution of 2-3 mm in both two and three dimensions, and mice experiments have shown successful SPECT imaging of small organs. 31) images obtained from a paraffin cylinder phantom and from a Tc-99m water solution phantom showed that a "hot" spot with a size down to 0.2ml can be detected with a resolution of about 2 mm if the tumor to background activity ratio is 6: 1. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:141 / 149
页数:9
相关论文
共 12 条
[2]  
ARCHIMANDRITIS S, 2000, 8 PIS M ADV DET LA B
[3]   First results from a YAP:Ce gamma camera for small animal studies [J].
deNotaristefani, F ;
Pani, R ;
Scopinaro, F ;
Barone, LM ;
Blazek, K ;
DeVincentis, G ;
Malatesta, T ;
Maly, P ;
Pellegrini, R ;
Pergola, A ;
Soluri, A ;
Vittori, F .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (06) :3264-3271
[4]  
HERMAN GT, 1980, IMAGE RECONSTRUCTION
[5]  
KAK C, 1987, SLANEY PRINCIPLES CO
[6]  
KONTAXAKIS G, 1998, MAXIMUM LIKELIHOOD A
[7]   A THEORETICAL-STUDY OF SOME MAXIMUM-LIKELIHOOD ALGORITHMS FOR EMISSION AND TRANSMISSION TOMOGRAPHY [J].
LANGE, K ;
BAHN, M ;
LITTLE, R .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1987, 6 (02) :106-114
[8]  
LOUDOS GK, 2000, IEEE NUCL SCI S MED
[9]   Development of an application specific scintimammography detector based on a crystal scintillator array and a PSPMT [J].
Majewski, S ;
Farzanpay, F ;
Goode, A ;
Kross, B ;
Steinbach, D ;
Weisenberger, A ;
Williams, M ;
Wojcik, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 409 (1-3) :520-523
[10]   Scintillating array gamma camera for clinical use [J].
Pani, R ;
Pellegrini, R ;
Scopinaro, F ;
Soluri, A ;
DeVincentis, G ;
Pergola, A ;
Iacopi, F ;
Corona, A ;
Grammatico, A ;
Filippi, S ;
Ballesio, PL .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 392 (1-3) :295-298