Ion mobility spectrometry-mass spectrometry performance using electrodynamic ion funnels and elevated drift gas pressures

被引:120
作者
Baker, Erin Shammel
Clowers, Brian H.
Li, Fumin
Tang, Keqi
Tolmachev, Aleksey V.
Prior, David C.
Belov, Mikhail E.
Smith, Richard D.
机构
[1] Pacific NW Natl Lab, Biol Sci Div, Richland, WA 99352 USA
[2] Pacific NW Natl Lab, Environm Mol Sci Lab, Richland, WA 99352 USA
关键词
D O I
10.1016/j.jasms.2007.03.031
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The ability of ion mobility spectrometry coupled with mass spectrometry (IMS-MS) to characterize biological mixtures has been illustrated over the past eight years. However, the challenges posed by the extreme complexity of many biological samples have demonstrated the need for higher resolution IMS-MS measurements. We have developed a higher resolution ESI-IMS-TOF MS by utilizing high-pressure electrodynamic ion funnels at both ends of the IMS drift cell and operating the drift cell at an elevated pressure compared with that conventionally used. The ESI-IMS-TOF MS instrument consists of an ESI source, an hourglass ion funnel used for ion accumulation/injection into an 88 cm drift cell, followed by a 10 cm ion funnel and a commercial orthogonal time-of-flight mass spectrometer providing high mass measurement accuracy. It was found that the rear ion funnel could be effectively operated as an extension of the drift cell when the DC fields were matched, providing an effective drift region of 98 cm. The resolution of the instrument was evaluated at pressures ranging from 4 to 12 torr and ion mobility drift voltages of 16 V/cm (4 torr) to 43 V/cm (12 torr). An increase in resolution from 55 to 80 was observed from 4 to 12 torr nitrogen drift gas with no significant loss in sensitivity. The choice of drift gas was also shown to influence the degree of ion heating and relative trapping efficiency within the ion funnel.
引用
收藏
页码:1176 / 1187
页数:12
相关论文
共 47 条
[1]   Toward a human blood serum proteome - Analysis by multidimensional separation coupled with mass spectrometry [J].
Adkins, JN ;
Varnum, SM ;
Auberry, KJ ;
Moore, RJ ;
Angell, NH ;
Smith, RD ;
Springer, DL ;
Pounds, JG .
MOLECULAR & CELLULAR PROTEOMICS, 2002, 1 (12) :947-955
[2]  
[Anonymous], UNPUB
[3]   Effects of drift-gas polarizability on glycine peptides in ion mobility spectrometry [J].
Beegle, LW ;
Kanik, I ;
Matz, L ;
Hill, HH .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 216 (03) :257-268
[4]   Ion discrimination during ion accumulation in a quadrupole interface external to a Fourier transform ion cyclotron resonance mass spectrometer [J].
Belov, ME ;
Nikolaev, EN ;
Harkewicz, R ;
Masselon, CD ;
Alving, K ;
Smith, RD .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 208 (1-3) :205-225
[5]   GAS-PHASE ION CHROMATOGRAPHY - TRANSITION-METAL STATE SELECTION AND CARBON CLUSTER FORMATION [J].
BOWERS, MT ;
KEMPER, PR ;
VON HELDEN, G ;
VANKOPPEN, PAM .
SCIENCE, 1993, 260 (5113) :1446-1451
[6]  
Clemmer DE, 1997, J MASS SPECTROM, V32, P577
[7]   High-order structure and dissociation of gaseous peptide aggregates that are hidden in mass spectra [J].
Counterman, AE ;
Valentine, SJ ;
Srebalus, CA ;
Henderson, SC ;
Hoaglund, CS ;
Clemmer, DE .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (08) :743-759
[8]   High-resolution ion mobility measurements [J].
Dugourd, P ;
Hudgins, RR ;
Clemmer, DE ;
Jarrold, MF .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (02) :1122-1129
[9]   ELECTROSPRAY IONIZATION-PRINCIPLES AND PRACTICE [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
MASS SPECTROMETRY REVIEWS, 1990, 9 (01) :37-70
[10]   Application of ion mobility to the gas-phase conformational analysis of polyhedral oligomeric silsesquioxanes (POSS) [J].
Gidden, J ;
Kemper, PR ;
Shammel, E ;
Fee, DP ;
Anderson, S ;
Bowers, MT .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2003, 222 (1-3) :63-73