Semiautomated quantification of hepatitis B virus DNA in a routine diagnostic laboratory

被引:18
作者
Kessler, HH
Stelzl, E
Daghofer, E
Santner, BI
Marth, E
Lackner, H
Stauber, RE
机构
[1] Karl Franzens Univ Graz, Mol Diagnost Lab, Inst Hyg, A-8010 Graz, Austria
[2] Karl Franzens Univ Graz, Dept Pediat, A-8010 Graz, Austria
[3] Karl Franzens Univ Graz, Dept Internal Med, A-8010 Graz, Austria
关键词
D O I
10.1128/CDLI.7.5.853-855.2000
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
The Cobas Amplicor HBV Monitor test for quantitative determination of hepatitis B virus (HBV) DNA in serum has recently been introduced. To evaluate the performance of this assay in a routine diagnostic laboratory, reproducibility of results was determined with the First European Union Concerted Action HBV Proficiency Panel and the Accurun 325 HBV DNA Positive Control, Series 300. Results for 270 routine serum samples were additionally evaluated. To avoid the retesting of a large number of samples due to titers exceeding the upper limit for the linear range of the assay, sera of patients with chronic hepatitis B (CHB) were diluted prior to the assay to 10(-4) in normal human plasma, which is included in the assay. The mean coefficient of variation was 22.9% for all input HBV DNAs. Of 270 routine serum samples, 182 (150 sera from transplant donors and 32 sera from patients who had recovered from CHB) tested negative. Eighty-six sera were found to be HBV DNA positive; in six sera, HBV DNA levels were found to exceed the upper limit for the linear range of the assay and had to be retested. In the remaining two sera, inhibition occurred. The semiautomated Cobas Amplicor HBV Monitor test showed sufficient reproducibility and helped in avoiding human error. The relatively narrow linear range of detection is a limitation of the new assay.
引用
收藏
页码:853 / 855
页数:3
相关论文
共 15 条
[1]   Evaluation of the COBAS AMPLICOR MTB system [J].
Bodmer, T ;
Gurtner, A ;
Scholkmann, M ;
Matter, L .
JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (06) :1604-1605
[2]   Clinical evaluation and applications of the Amplicor HBV Monitor™ test, a quantitative HBV DNA PCR assay [J].
Gerken, G ;
Gomes, J ;
Lampertico, P ;
Colombo, M ;
Rothaar, T ;
Trippler, M ;
Colucci, G .
JOURNAL OF VIROLOGICAL METHODS, 1998, 74 (02) :155-165
[3]   Comparison of three commercially available amplification assays, AMP CT, LCx, and COBAS AMPLICOR, for detection of Chlamydia trachomatis in first-void urine [J].
Goessens, WHF ;
Mouton, JW ;
vanderMeijden, WI ;
Deelen, S ;
vanRijsoortVos, TH ;
Toom, NLD ;
Verbrugh, HA ;
Verkooyen, RP .
JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (10) :2628-2633
[4]   INHIBITION OF HUMAN-IMMUNODEFICIENCY-VIRUS GENE AMPLIFICATION BY HEPARIN [J].
HOLODNIY, M ;
KIM, S ;
KATZENSTEIN, D ;
KONRAD, M ;
GROVES, E ;
MERIGAN, TC .
JOURNAL OF CLINICAL MICROBIOLOGY, 1991, 29 (04) :676-679
[5]   Evaluation of automated COBAS AMPLICOR PCR system for detection of several infectious agents and its impact on laboratory management [J].
Jungkind, D ;
DiRenzo, S ;
Beavis, KG ;
Silverman, NS .
JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (11) :2778-2783
[6]  
KATCHER HL, 1994, BIOTECHNIQUES, V16, P84
[7]   Evaluation of a new assay for HBV DNA quantitation in patients with chronic hepatitis B [J].
Kessler, HH ;
Pierer, K ;
Dragon, E ;
Lackner, H ;
Santner, B ;
Stunzner, D ;
Stelzl, E ;
Waitzl, B ;
Marth, E .
CLINICAL AND DIAGNOSTIC VIROLOGY, 1998, 9 (01) :37-43
[8]   Identification of different states of hepatitis B virus infection with a quantitative PCR assay [J].
Kessler, HH ;
Preininger, S ;
Stelzl, E ;
Daghofer, E ;
Santner, BI ;
Marth, E ;
Lackner, H ;
Stauber, RE .
CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2000, 7 (02) :298-300
[9]   Performance of the automated COBAS AMPLICOR(TM) system for the detection of hepatitis C virus RNA [J].
Kessler, HH ;
Dragon, EA ;
Pierer, K ;
Santner, BI ;
Liao, YH ;
Stunzner, D ;
Stelzl, E ;
Marth, E .
CLINICAL AND DIAGNOSTIC VIROLOGY, 1997, 7 (03) :139-145
[10]   Automated quantitative analysis of hepatitis B virus DNA by using the cobas Amplicor HBV Monitor test [J].
Noborg, U ;
Gusdal, A ;
Pisa, EK ;
Hedrum, A ;
Lindh, M .
JOURNAL OF CLINICAL MICROBIOLOGY, 1999, 37 (09) :2793-2797