Adaptive Cancellation of Floor Vibrations in Standing Ballistocardiogram Measurements Using a Seismic Sensor as a Noise Reference

被引:28
作者
Inan, Omer T. [1 ]
Etemadi, Mozziyar [1 ]
Widrow, Bernard [1 ]
Kovacs, Gregory T. A. [2 ]
机构
[1] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[2] DARPA, Microelect Technol Off, Arlington, VA 22203 USA
关键词
Adaptive noise cancellation; ballistocardiogram (BCG); cardiovascular disease; physiological monitoring;
D O I
10.1109/TBME.2009.2018831
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An adaptive noise canceller was used to reduce the effect of floor vibrations on ballistocardiogram (BCG) measurements from a modified electronic bathroom scale. A seismic sensor was placed next to the scale on the floor and used as the noise reference input to the noise canceller. BCG recordings were acquired from a healthy subject while another person stomped around the scale, thus causing increased floor vibrations. The noise canceller substantially eliminated the artifacts in the BCG signal due to these vibrations without distorting the morphology of the measured BCG. Additionally, recordings were obtained from another subject standing inside a parked bus while the engine was running. The artifacts due to the vibrations of the engine, and the other vehicles moving on the road next to the bus, were also effectively eliminated by the noise canceller. The system with automatic floor vibration cancellation could be used to increase BCG measurement robustness in home monitoring applications. Additionally, the noise cancellation approach may enable BCG recording in ambulances-or other transport vehicles-where noninvasive hemodynamic monitoring may otherwise not be feasible.
引用
收藏
页码:722 / 727
页数:6
相关论文
共 12 条
[1]   A NEW METHOD FOR LONG-TERM MONITORING OF THE BALLISTOCARDIOGRAM, HEART-RATE, AND RESPIRATION [J].
ALIHANKA, J ;
VAAHTORANTA, K ;
SAARIKIVI, I .
AMERICAN JOURNAL OF PHYSIOLOGY, 1981, 240 (05) :R384-R392
[2]  
[Anonymous], 1985, Adaptive signal processing prentice-hall
[3]  
Brown H.R., 1952, CLIN BALLISTOCARDIOG
[4]   SOME TECHNICS FOR RECORDING THE BALLISTOCARDIOGRAM DIRECTLY FROM THE BODY [J].
DOCK, W ;
TAUBMAN, F .
AMERICAN JOURNAL OF MEDICINE, 1949, 7 (06) :751-757
[5]   Robust ballistocardiogram acquisition for home monitoring [J].
Inan, O. T. ;
Etemadi, M. ;
Wiard, R. M. ;
Giovangrandi, L. ;
Kovacs, G. T. A. .
PHYSIOLOGICAL MEASUREMENT, 2009, 30 (02) :169-185
[6]   Evaluating the foot electromyogram signal as a noise reference for a bathroom scale ballistocardiogram recorder [J].
Inan, Omer T. ;
Etemadi, Mozziyar ;
Wiard, Richard M. ;
Giovangrandi, Laurent ;
Kovacs, Gregory T. A. .
PROCEEDINGS OF THE 21ST IEEE INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, 2008, :70-+
[7]  
INAN OT, 2008, P IEEE EMBC VANC BC, P674
[8]  
KOIVISTOINEN T, P IEMBS 04 26 ANN IN, P2026
[9]   The design of the ballistocardiograph [J].
Nickerson, JL ;
Curtis, HJ .
AMERICAN JOURNAL OF PHYSIOLOGY, 1944, 142 (01) :1-11
[10]   Studies on the estimation of cardiac ouptut in man, and of abnormalities in cardiac function, from the heart's recoil and the blood's impacts; The ballistocardiogram [J].
Starr, I ;
Rawson, AJ ;
Schroeder, HA ;
Joseph, NR .
AMERICAN JOURNAL OF PHYSIOLOGY, 1939, 127 (01) :1-28