On the relative importance of rheology for image-based CFD models of the carotid bifurcation

被引:141
作者
Lee, Sang-Wook [1 ]
Steinman, David A.
机构
[1] Univ Toronto, Dept Mech & Ind Engn, Toronto, ON M5S 3G8, Canada
[2] Univ Toronto, Dept Mech & Ind Engn, Inst Biomat & Biomed Engn, Toronto, ON M5S 3G8, Canada
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2007年 / 129卷 / 02期
关键词
computational fluid dynamics; non-Newtonian rheology; carotid bifurcation; wall shear stress; hematocrit;
D O I
10.1115/1.2540836
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Background: Patient-specific computational fluid dynamics (CFD) models derived from medical images often require simplifying assumptions to render the simulations conceptually or computationally tractable. In this study, we investigated the sensitivity of image-based CFD models of the carotid bifurcation to assumptions regarding the blood rheology. Method of Approach: CFD simulations of three different patient-specific models were carried out assuming: a reference high-shear Newtonian viscosity, two different non-Newtonian (shear-thinning) rheology models, and Newtonian viscosities based on characteristic shear rates or, equivalently, assumed hematocrits. Sensitivity of wall shear stress (WSS) and oscillatory shear index (0S1) were contextualized with respect to the reproducibility of the reconstructed geometry, and to assumptions regarding the inlet boundary conditions. Results: Sensitivity of WSS to the various rheological assumptions was roughly 1.0 dyn/cm(2) or 8%, nearly seven times less than that due to geometric uncertainty (6.7 dyn/cm(2) or 47%), and on the order of that due to inlet boundary condition assumptions. Similar trends were observed regarding OSI sensitivity. Rescaling the Newtonian viscosity based on time-averaged inlet shear rate served to approximate reasonably, if overestimate slightly, non-Newtonian behavior. Conclusions: For image-based CFD simulations of the normal carotid bifurcation, the assumption of constant viscosity at a nominal hematocrit is reasonable in light of currently available levels of geometric precision, thus serving to obviate the need to acquire patient-specific rheological data.
引用
收藏
页码:273 / 278
页数:6
相关论文
共 30 条
[1]   Robust and objective decomposition and mapping of bifurcating vessels [J].
Antiga, L ;
Steinman, DA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (06) :704-713
[2]  
BALLYK PD, 1994, BIORHEOLOGY, V31, P565
[3]   The influence of flow, vessel diameter, and non-Newtonian blood viscosity on the wall shear stress in a carotid bifurcation model for unsteady flow [J].
Box, FMA ;
van der Geest, RJ ;
Rutten, MCM ;
Reiber, JHC .
INVESTIGATIVE RADIOLOGY, 2005, 40 (05) :277-294
[4]   Numerical investigation of the non-Newtonian pulsatile blood flow in a bifurcation model with a non-planar branch [J].
Chen, J ;
Lu, XY .
JOURNAL OF BIOMECHANICS, 2006, 39 (05) :818-832
[5]  
CHO YI, 1991, BIORHEOLOGY, V28, P241
[6]   RHEOLOGY AND HEMODYNAMICS [J].
COKELET, GR .
ANNUAL REVIEW OF PHYSIOLOGY, 1980, 42 :311-324
[7]  
Deville MO, 2002, HIGH ORDER METHODS I
[8]   Steady flow separation patterns in a 45 degree junction [J].
Ethier, CR ;
Prakash, S ;
Steinman, DA ;
Leask, RL ;
Couch, GG ;
Ojha, M .
JOURNAL OF FLUID MECHANICS, 2000, 411 :1-38
[9]  
ETHIER CR, 1999, ADV COMP BIOENGN, P131
[10]   EFFECTS OF ARTERIAL COMPLIANCE AND NON-NEWTONIAN RHEOLOGY ON CORRELATIONS BETWEEN INTIMAL THICKNESS AND WALL SHEAR [J].
FRIEDMAN, MH ;
BARGERON, CB ;
DUNCAN, DD ;
HUTCHINS, GM ;
MARK, FF .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1992, 114 (03) :317-320