Myocardial electrical impedance responds to ischemia and reperfusion in humans

被引:18
作者
Dzwonczyk, R
del Rio, C
Brown, DA
Michler, RE
Wolf, RK
Howie, MB
机构
[1] Ohio State Univ, Dept Anesthesiol, Columbus, OH 43210 USA
[2] Ohio State Univ, Dept Anesthesiol, Columbus, OH 44903 USA
[3] MedCent, Mansfield, OH 44903 USA
[4] Ohio State Univ, Div Cardiothorac Surg, Dept Surg, Columbus, OH 43210 USA
关键词
ischemia; myocardial electrical impedance; reperfusion;
D O I
10.1109/TBME.2004.834297
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Myocardial electrical impedance (MEI) is correlated to ischemia and reperfusion of the heart muscle. The entire body of Work with MEI to this point has been carried out in animal subjects in vivo and excised tissue samples. In this study, we measured MEI clinically for the first time in human patients who were undergoing off-pump coronary artery bypass (OPCAB) surgery. MEI was measured with a monitor designed in this laboratory and approved by the FDA for use on human subjects. Our patient population (n = 18) had a 70%-100% stenosis, of the diseased coronary artery targeted for bypass. We measured MEI continuously during surgery and at 3, 6, 24, and 72 h postoperatively from two temporary pacing electrodes attached to the heart muscle. Absolute baseline impedance ranged from 173 to 729 Omega. MEI increased with occlusion of the diseased artery prior to bypass. The percent increase from baseline was inversely correlated to the percent stenosis of the diseased artery. MEI decreased below baseline immediately on reperfusion following bypass in all patients and continued decreasing over the measurement period. MEI is a reliable clinical indicator of ischemia and reperfusion in humans and may indicate the effectiveness of coronary artery surgery. The parameter may have monitoring and diagnostic value in heart disease in humans.
引用
收藏
页码:2206 / 2209
页数:4
相关论文
共 10 条
[1]  
Dzwonczyk R, 1992, COMPUT CARDIOL, V19, P575
[2]  
DZWONCZYK R, 1995, Patent No. 5454377
[3]   ONLINE DETECTION OF REVERSIBLE MYOCARDIAL ISCHEMIC-INJURY BY MEASUREMENT OF MYOCARDIAL ELECTRICAL-IMPEDANCE [J].
ELLENBY, MI ;
SMALL, KW ;
WELLS, RM ;
HOYT, DJ ;
LOWE, JE .
ANNALS OF THORACIC SURGERY, 1987, 44 (06) :587-597
[4]   BIOELECTRICAL TISSUE RESISTANCE DURING VARIOUS METHODS OF MYOCARDIAL PRESERVATION [J].
GARRIDO, H ;
SUEIRO, J ;
RIVAS, J ;
VILCHES, J ;
ROMERO, JM ;
GARRIDO, F .
ANNALS OF THORACIC SURGERY, 1983, 36 (02) :143-151
[5]  
GEBHARD MM, 1987, THORAC CARDIOV SURG, V35, P26
[6]  
Grauhan O, 1996, J HEART LUNG TRANSPL, V15, P136
[7]  
Howie MB, 2001, ANESTH ANALG, V92, P12
[8]  
MUELLER J, AM SOC EXTR TECHN P, P49
[9]   Intramyocardial impedance measurements for diagnosis of acute cardiac allograft rejection [J].
Pfitzmann, R ;
Müller, J ;
Grauhan, O ;
Hetzer, R .
ANNALS OF THORACIC SURGERY, 2000, 70 (02) :527-532
[10]   INTRAMURAL RESISTIVITY OF CARDIAC TISSUE [J].
VANOOSTEROM, A ;
DEBOER, RW ;
VANDAM, RT .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1979, 17 (03) :337-343