Flipped patellar tendon autograft anterior cruciate ligament reconstruction

被引:32
作者
Barber, FA [1 ]
机构
[1] Plano Orthoped & Sports Med Ctr, Plano, TX 75093 USA
关键词
ACL reconstruction; flip; patellar tendon autograft; interference fixation; bioscrew; isometric; tunnel mismatch;
D O I
10.1053/jars.2000.4384
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To determine the efficacy of an anterior cruciate ligament (ACL) graft that customizes length and facilitates anatomic outlet fixation, a prospective study of the "flipped" patellar tendon autograft ACL reconstruction began in 1995. This technique shortens the tendon portion to match the intra-articular length by rotating 1 bone plug 180 degrees proximally onto the tendon, thus flipping the bone plug over its ligamentous insertion. Bioscrews (poly L-lactic acid; Linvatec, Large, FL) secured the grafts. All patients undergoing this procedure with a minimum 21 months follow-up were reviewed. Preoperative and postoperative Tegner, Lysholm, and IKDC activity scores, and Lachman and pivot shift tests were obtained. Postoperative KT testing and radiographs were obtained. Fifty patients were followed-up for an average of 28 months (range, 21 to 39 months). Average patient age was 34 years (range, 16 to 52 years). Tegner scores increased from 2.0 preoperatively to 6.0 postoperatively. Lysholm scores increased from 46 preoperatively to 93 at follow-up, with 86% excellent (66%) or good (20%). IKDC activity scores increased from 3.1 preoperatively to 1.7 postoperatively. KT manual-maximum difference at follow-up averaged 0.7 mm, with 74% less than 3-mm, 18% 3- to 5-mm, and 8% greater than 5-mm difference. Postoperative Lachman results were 0 in 45 patients and 1+ in 5 patients. Postoperative pivot shift was absent in all but 1 patient. Full extension was achieved in all cases and flexion averaged 136 degrees with no patient having less than 120 degrees flexion. No lytic bone changes or tunnel widening were seen. The flipped patellar tendon autograft reduces graft length to its intra-articular portion, increasing graft stability, isometry, and stiffness, and avoiding tunnel graft mismatch with clinically excellent results.
引用
收藏
页码:483 / 490
页数:8
相关论文
共 28 条
[1]
ADATE JA, 1998, ARTHROSCOPY, V14, P278
[2]
ALM A, 1974, ACTA CHIR SCAND, V140, P289
[3]
PRELIMINARY-RESULTS OF AN ABSORBABLE INTERFERENCE SCREW [J].
BARBER, FA ;
ELROD, BF ;
MCGUIRE, DA ;
PAULOS, LE .
ARTHROSCOPY, 1995, 11 (05) :537-548
[4]
OSTEOLYTIC CHANGES ACCOMPANYING DEGRADATION OF ABSORBABLE FRACTURE FIXATION IMPLANTS [J].
BOSTMAN, OM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (04) :679-682
[6]
BROSTROM L, 1968, LAKRTIDN, V64, P44
[7]
ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION USING 1/3 OF THE PATELLAR LIGAMENT, AUGMENTED BY EXTRA-ARTICULAR TENDON TRANSFERS [J].
CLANCY, WG ;
NELSON, DA ;
REIDER, B ;
NARECHANIA, RG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (03) :352-359
[8]
Factors affecting isometry of endoscopic anterior cruciate ligament reconstruction: The effect of guide offset and rotation [J].
Cooper, DE ;
Urrea, L ;
Small, J .
ARTHROSCOPY, 1998, 14 (02) :164-170
[9]
Edwards D J, 1994, J Shoulder Elbow Surg, V3, P230, DOI 10.1016/S1058-2746(09)80040-2
[10]
Tibial tunnel bone grafting: A new technique for dealing with graft-tunnel mismatch in endoscopic anterior cruciate ligament reconstruction [J].
Fowler, BL ;
DiStefano, VJ .
ARTHROSCOPY, 1998, 14 (02) :224-228