摘要
Objective:To evaluate hemodynamic and clinical responses to induction of anesthesia and intubation at 3 different values of the electroencephalogram bispectral index (BIS). Design: Prospective randomized trial. Setting: University-affiliate hospital. Participants: Forty-five patients undergoing elective coronary artery bypass graft surgery. Interventions: Patients were assigned to 3 groups (n = 15 for each group). Anesthesia was induced with midazolam, sufentanil, and pancuronium. In each group, sufentanil was titrated to a BIS value of 60, 50, or 40 before intubation. Mean arterial blood pressure, heart rate, incidence of coughing, tearing, and need for fluid replacement or injections of norepinephrine were recorded before intubation as well as immediately and 1 and 2 minutes after intubation. Measurements and Main Results: Thirteen patients intubated at a BIS value of 60 coughed and 14 experienced tearing after intubation, whereas no patient of the other groups showed signs of arousal. Mean arterial blood pressure remained stable in the BIS 60 and 50 groups, whereas in the BIS 40 group it decreased significantly to lower values before and after intubation, Patients in the BIS 40 group needed significantly more fluid replacement and injections of norepinephrine compared with the other groups. No significant changes in heart rate were detected. Conclusions: Electroencephalogram BIS predicts hemodynamic and arousal reaction resulting from induction of anesthesia and endotracheal intubation. BIS value should be kept at 50 before intubation to ensure safe hemodynamic conditions during induction of anesthesia in cardiac surgical patients. Copyright (C) 2000 by W.B. Saunders Company.
引用
收藏
页码:693 / 697
页数:5
相关论文
共 23 条
[1]   Relationship between calculated blood concentration of propofol and electrophysiological variables during emergence from anaesthesia: Comparison of bispectral index, spectral edge frequency, median frequency and auditory evoked potential index [J].
Doi, M ;
Gajraj, RJ ;
Mantzaridis, H ;
Kenny, GNC .
BRITISH JOURNAL OF ANAESTHESIA, 1997, 78 (02) :180-184
[2]   A COMPARISON OF MEDIAN FREQUENCY, SPECTRAL EDGE FREQUENCY, A FREQUENCY BAND POWER RATIO, TOTAL POWER, AND DOMINANCE SHIFT IN THE DETERMINATION OF DEPTH OF ANESTHESIA [J].
DRUMMOND, JC ;
BRANN, CA ;
PERKINS, DE ;
WOLFE, DE .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1991, 35 (08) :693-699
[3]   THE ELECTROENCEPHALOGRAM DOES NOT PREDICT DEPTH OF ISOFLURANE ANESTHESIA [J].
DWYER, RC ;
RAMPIL, IJ ;
EGER, EI ;
BENNETT, HL .
ANESTHESIOLOGY, 1994, 81 (02) :403-409
[4]  
FREYE E, 1995, OPIOIDE MED, P155
[5]   Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in healthy volunteers [J].
Glass, PS ;
Bloom, M ;
Kearse, L ;
Rosow, C ;
Sebel, P ;
Manberg, P .
ANESTHESIOLOGY, 1997, 86 (04) :836-847
[6]   Assessment of anaesthesia depth [J].
Heier, T ;
Steen, PA .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1996, 40 (09) :1087-1100
[7]   The bispectral index during induction of anesthesia with midazolam and propofol [J].
Hoffman, WE ;
Zsigmond, E ;
Albrecht, RF .
JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 1996, 8 (01) :15-20
[8]   BISPECTRAL ANALYSIS OF THE ELECTROENCEPHALOGRAM CORRELATES WITH PATIENT MOVEMENT TO SKIN INCISION DURING PROPOFOL NITROUS-OXIDE ANESTHESIA [J].
KEARSE, LA ;
MANBERG, P ;
CHAMOUN, N ;
DEBROS, F ;
ZASLAVSKY, A .
ANESTHESIOLOGY, 1994, 81 (06) :1365-1370
[9]  
Kobayashi T, 1996, Masui, V45, P1335
[10]   Controlling the hemodynamic response to laryngoscopy and endotracheal intubation [J].
Kovac, AL .
JOURNAL OF CLINICAL ANESTHESIA, 1996, 8 (01) :63-79