Recommendations for blood pressure measurement in humans and experimental animals - Part 2: Blood pressure measurement in experimental animals - A statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research

被引:234
作者
Kurtz, TW
Griffin, KA
Bidani, AK
Davisson, RL
Hall, JE
机构
关键词
blood pressure; blood pressure determination; blood pressure monitoring; hypertension; experimental;
D O I
10.1161/01.HYP.0000150857.39919.cb
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
In experimental animals, as in humans, techniques for measuring blood pressure ( BP) have improved considerably over the past decade. In this document, we present recommendations for measuring BP in experimental animals with the goal of helping investigators select optimal methods for BP monitoring in the research laboratory. The advantages and disadvantages of various BP measurement methods are discussed and specific recommendations are provided for selecting the optimal technique depending on the study objective. Although indirect techniques that permit only sporadic measurements of BP may be suitable for some purposes, methods for directly measuring BP are generally preferred because of their ability to monitor the highly dynamic nature of BP in a comprehensive fashion. Selection of the methods to be used should ultimately be guided by the study objectives to insure that the techniques chosen are appropriate for the experimental questions being explored.
引用
收藏
页码:299 / 310
页数:12
相关论文
共 87 条
[1]   Telemetry for cardiovascular monitoring in a pharmacological study - New approaches to data analysis [J].
Anderson, NH ;
Devlin, AM ;
Graham, D ;
Morton, JJ ;
Hamilton, CA ;
Reid, JL ;
Schork, NJ ;
Dominiczak, AF .
HYPERTENSION, 1999, 33 (01) :248-255
[2]   MOUSE STRAIN DIFFERENCES IN SUSCEPTIBILITY TO CEREBRAL-ISCHEMIA ARE RELATED TO CEREBRAL VASCULAR ANATOMY [J].
BARONE, FC ;
KNUDSEN, DJ ;
NELSON, AH ;
FEUERSTEIN, GZ ;
WILLETTE, RN .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1993, 13 (04) :683-692
[3]   CONTINUOUS TELEMETRIC BLOOD-PRESSURE MONITORING AND GLOMERULAR INJURY IN THE RAT REMNANT KIDNEY MODEL [J].
BIDANI, AK ;
GRIFFIN, KA ;
PICKEN, M ;
LANSKY, DM .
AMERICAN JOURNAL OF PHYSIOLOGY, 1993, 265 (03) :F391-F398
[4]   Lack of evidence of blood pressure-independent protection by renin-angiotensin system blockade after renal ablation [J].
Bidani, AK ;
Griffin, KA ;
Bakris, G ;
Picken, MM .
KIDNEY INTERNATIONAL, 2000, 57 (04) :1651-1661
[5]   Step vs. "dynamic" autoregulation: implications for susceptibility to hypertensive injury [J].
Bidani, AK ;
Hacioglu, R ;
Abu-Amarah, I ;
Williamson, GA ;
Loutzenhiser, R ;
Griffin, KA .
AMERICAN JOURNAL OF PHYSIOLOGY-RENAL PHYSIOLOGY, 2003, 285 (01) :F113-F120
[6]   Long-term renal consequences of hypertension for normal and diseased kidneys [J].
Bidani, AK ;
Griffin, KA .
CURRENT OPINION IN NEPHROLOGY AND HYPERTENSION, 2002, 11 (01) :73-80
[7]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[8]   A NEW METHOD FOR CONTINUOUS CHRONIC MEASUREMENT AND RECORDING OF BLOOD-PRESSURE, HEART-RATE AND ACTIVITY IN THE RAT VIA RADIOTELEMETRY [J].
BROCKWAY, BP ;
MILLS, PA ;
AZAR, SH .
CLINICAL AND EXPERIMENTAL HYPERTENSION PART A-THEORY AND PRACTICE, 1991, 13 (05) :885-895
[9]   TAIL-CUFF BLOOD-PRESSURE MEASUREMENT WITHOUT EXTERNAL PREHEATING IN AWAKE RATS [J].
BUNAG, RD ;
BUTTERFIELD, J .
HYPERTENSION, 1982, 4 (06) :898-903
[10]  
BUNAG RD, 1983, CLIN EXP HYPERTENS A, V5, P1659