A sentinel sensor network for hydrogen sensing

被引:88
作者
Grimes, CA
Ong, KG
Varghese, OK
Yang, XP
Mor, G
Paulose, M
Dickey, EC
Ruan, CM
Pishko, MV
Kendig, JW
Mason, AJ
机构
[1] Penn State Univ, Dept Elect Engn, University Pk, PA 16802 USA
[2] Penn State Univ, Inst Mat Res, University Pk, PA 16802 USA
[3] SenTech Corp, State Coll, PA 16803 USA
[4] Penn State Univ, Dept Mat Sci & Engn, University Pk, PA 16802 USA
[5] Penn State Univ, Dept Chem Engn, University Pk, PA 16802 USA
[6] Penn State Univ, Childrens Hosp, Div Newborn Med, Milton S Hershey Med Ctr, Hershey, PA 17033 USA
[7] Michigan State Univ, Dept Elect & Comp Engn, Lansing, MI USA
关键词
sensor network; sensor node; sensor array; hydrogen; sensor; nanotube;
D O I
10.3390/s30300069
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A wireless sensor network is presented for in-situ monitoring of atmospheric hydrogen concentration. The hydrogen sensor network consists of multiple sensor nodes, equipped with titania nanotube hydrogen sensors, distributed throughout the area of interest; each node is both sensor, and data-relay station that enables extended wide area monitoring without a consequent increase of node power and thus node size. The hydrogen sensor is fabricated from a sheet of highly ordered titania nanotubes, made by anodization of a titanium thick film, to which platinum electrodes are connected. The electrical resistance of the hydrogen sensor varies from 245 Omega at 500 ppm hydrogen, to 10.23 kOmega at 0 ppm hydrogen ( pure nitrogen environment). The measured resistance is converted to voltage, 0.049 V at 500 ppm to 2.046 V at 0 ppm, by interface circuitry. The microcontroller of the sensor node digitizes the voltage and transmits the digital information, using intermediate nodes as relays, to a host node that downloads measurement data to a computer for display. This paper describes the design and operation of the sensor network, the titania nanotube hydrogen sensors with an apparent low level resolution of approximately 0.05 ppm, and their integration in one widely useful device.
引用
收藏
页码:69 / 82
页数:14
相关论文
共 34 条
  • [1] Wireless sensor networks: a survey
    Akyildiz, IF
    Su, W
    Sankarasubramaniam, Y
    Cayirci, E
    [J]. COMPUTER NETWORKS, 2002, 38 (04) : 393 - 422
  • [2] Breath hydrogen concentrations of cats given commercial canned and extruded diets indicate gastrointestinal microbial activity vary with diet type
    Backus, RC
    Puryear, LM
    Crouse, BA
    Biourge, VC
    Rogers, QR
    [J]. JOURNAL OF NUTRITION, 2002, 132 (06) : 1763S - 1766S
  • [3] MECHANISMS FOR HYDROGEN DIFFUSION IN TIO2
    BATES, JB
    WANG, JC
    PERKINS, RA
    [J]. PHYSICAL REVIEW B, 1979, 19 (08): : 4130 - 4139
  • [4] Diagnosis of small intestinal bacterial overgrowth in patients with cirrhosis of the liver:: poor performance of the glucose breath hydrogen test
    Bauer, TM
    Schwacha, H
    Steinbrückner, B
    Brinkmann, FE
    Ditzen, AK
    Kist, M
    Blum, HE
    [J]. JOURNAL OF HEPATOLOGY, 2000, 33 (03) : 382 - 386
  • [5] Impact of necrotizing enterocolitis on length of stay and hospital charges in very low birth weight infants
    Bisquera, JA
    Cooper, TR
    Berseth, CL
    [J]. PEDIATRICS, 2002, 109 (03) : 423 - 428
  • [6] Breath hydrogen testing identifies patients with diabetic gastroparesis
    Burge, MR
    Tuttle, MS
    Violett, JL
    Stephenson, CL
    Schade, DS
    [J]. DIABETES CARE, 2000, 23 (06) : 860 - 861
  • [7] BREATH HYDROGEN EXCRETION AS A SCREENING-TEST FOR THE EARLY DIAGNOSIS OF NECROTIZING ENTEROCOLITIS
    CHEU, HW
    BROWN, DR
    ROWE, MI
    [J]. AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1989, 143 (02): : 156 - 159
  • [8] Gastric emptying and orocecal transit time in pregnancy
    Chiloiro, M
    Darconza, G
    Piccioli, E
    De Carne, M
    Clemente, C
    Riezzo, G
    [J]. JOURNAL OF GASTROENTEROLOGY, 2001, 36 (08) : 538 - 543
  • [9] Chong SKF, 2002, GASTROENTEROLOGY, V122, pA363
  • [10] DELIN KA, 2000, P 2000 IEEE AER C BI