The 50-millilitre syringe as an inexpensive training aid in the application of cricoid pressure

被引:33
作者
Flucker, CJR
Hart, E
Weisz, M
Griffiths, R
Ruth, M
机构
[1] Peterborough Dist Gen Hosp, Minist Def Hosp Unit, Peterborough PE3 6DA, England
[2] Peterborough Dist Gen Hosp, Dept Anaesthesia, Peterborough PE3 6DA, England
关键词
anaesthesia; larynx; laryngeal cartilages; cricoid; education; teaching; patient simulation;
D O I
10.1046/j.1365-2346.2000.00704.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
A recent study in our department demonstrated that depressing the plunger of a 50-mL syringe was reliably and linearly related to the force applied between 20 N and 50 N. Using a 50-mL syringe we constructed a simple device to help train anaesthetic assistants to apply cricoid pressure correctly. We then tested anaesthetists, operating department practitioners (non-physicians) and nurses in our hospital to see if they could correctly apply forces of 20 and 40 N. All subjects were then trained using this apparatus and once confident were retested immediately afterwards, and again 1 week and 1 month later. The results show a wide variation in the force applied with only 30% of subjects applying appropriate force at 20 N, and 40% at 40 N. Training leads to a significant improvement in performance (P < 0.005 at 20 N and P < 0.001 at 40 N) which is maintained for 1 week for both 20 N (P < 0.05) and 40 N (P < 0.05) but not for 1 month. Therefore training should be practised on a weekly basis. This is an inexpensive and simple device that we believe to be useful in helping anaesthetic assistants to apply effective cricoid pressure.
引用
收藏
页码:443 / 447
页数:5
相关论文
共 14 条
[1]   THE EFFECT OF CRICOID PRESSURE APPLICATION ON AIRWAY PATENCY [J].
ALLMAN, KG .
JOURNAL OF CLINICAL ANESTHESIA, 1995, 7 (03) :197-199
[2]  
Altman DG, 1991, PRACTICAL STAT MED R, P258
[3]   Use of a mechanical simulator for training in applying cricoid pressure [J].
Ashurst, N ;
Rout, CC ;
Rocke, BA ;
Gouws, E .
BRITISH JOURNAL OF ANAESTHESIA, 1996, 77 (04) :468-472
[4]   Cricoid pressure: Teaching the recommended level [J].
Herman, NL ;
Carter, B ;
VanDecar, TK .
ANESTHESIA AND ANALGESIA, 1996, 83 (04) :859-863
[5]   THE APPLICATION OF CRICOID PRESSURE - AN ASSESSMENT AND A SURVEY OF ITS PRACTICE [J].
HOWELLS, TH ;
CHAMNEY, AR ;
WRAIGHT, WJ ;
SIMONS, RS .
ANAESTHESIA, 1983, 38 (05) :457-460
[6]   THE CRICOID YOKE - A DEVICE FOR PROVIDING CONSISTENT AND REPRODUCIBLE CRICOID PRESSURE [J].
LAWES, EG ;
DUNCAN, PW ;
BLAND, B ;
GEMMEL, L ;
DOWNING, JW .
BRITISH JOURNAL OF ANAESTHESIA, 1986, 58 (08) :925-931
[7]   Cricoid pressure: knowledge and performance amongst anaesthetic assistants [J].
Meek, T ;
Gittins, N ;
Duggan, JE .
ANAESTHESIA, 1999, 54 (01) :59-62
[8]   RUPTURE OF THE ESOPHAGUS DURING CRICOID PRESSURE [J].
RALPH, SJ ;
WAREHAM, CA .
ANAESTHESIA, 1991, 46 (01) :40-41
[9]  
Ruth M. J., 1998, British Journal of Anaesthesia, V81, p292P
[10]  
SELLICK BA, 1961, LANCET, V2, P404