Kinetics of an enzyme-catalyzed reaction measured by electrospray ionization mass spectrometry using a simple rapid mixing attachment

被引:21
作者
Attwood, PV
Geeves, MA
机构
[1] Univ Western Australia, Sch Biomed & Chem Sci, Crawley, WA 6100, Australia
[2] Univ Kent, Dept Biosci, Canterbury CT2 7NJ, Kent, England
关键词
enzyme kinetics; rapid reaction; electrospray ionization mass spectrometry; trypsin;
D O I
10.1016/j.ab.2004.08.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Mass spectrometry offers a potential means of measuring virtually all enzyme-catalyzed reactions by simultaneously measuring the concentrations of substrates, products, and intermediates where there are differences in mass between them. To perform these measurements the reaction mixture must be aged for different times and then ionized. Electrospray ionization mass spectrometry provides the most direct means of measuring these reactions. Here we describe a simple reaction mixing and ageing attachment for an electrospray ionization mass spectrometer, built from commercially available components. We have employed this device to measure the kinetics of a model reaction, namely the hydrolysis of N-2-(carbobenzyloxy)-L-lysine-p-nitrophenyI ester-catalyzed by trypsin. In this way we were able to measure the kinetics of substrate depletion, product formation, and changes in both free enzyme and acyl-enzyme intermediate concentration in the approach to steady state. With this device we were able to measure reaction times down to about 640 ms. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:382 / 389
页数:8
相关论文
共 29 条
  • [1] STEADY-STATE AND PRE-STEADY-STATE KINETICS OF THE TRYPSIN-CATALYZED HYDROLYSIS OF "ALPHA-CBZ-L-LYSINE-PARA-NITROPHENYL ESTER
    ASCENZI, P
    MENEGATTI, E
    BORTOLOTTI, F
    GUARNERI, M
    ANTONINI, E
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA, 1981, 658 (01) : 158 - 164
  • [2] ON THE ANALYSIS OF BOVINE TRYPSIN BY ELECTROSPRAY MASS-SPECTROMETRY
    ASHTON, DS
    ASHCROFT, AE
    BEDDELL, CR
    COOPER, DJ
    GREEN, BN
    OLIVER, RWA
    [J]. BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1994, 199 (02) : 694 - 698
  • [3] BYRNE G, UCID30132 LAWR LIV N
  • [4] Mass spectrometric determination of association constants of adenylate kinase with two noncovalent inhibitors
    Daniel, JM
    McCombie, G
    Wendt, S
    Zenobi, R
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2003, 14 (05) : 442 - 448
  • [5] GANEM B, 1993, AM BIOTECHNOL LAB, V11, P32
  • [6] Going gently into flight: Analyzing noncovalent interactions by mass spectrometry
    Ganem, B
    Henion, JD
    [J]. BIOORGANIC & MEDICINAL CHEMISTRY, 2003, 11 (03) : 311 - 314
  • [7] OBSERVATION OF NONCOVALENT ENZYME SUBSTRATE AND ENZYME PRODUCT COMPLEXES BY ION-SPRAY MASS-SPECTROMETRY
    GANEM, B
    LI, YT
    HENION, JD
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1991, 113 (20) : 7818 - 7819
  • [8] A strategy for the determination of enzyme kinetics using electrospray ionization with an ion trap mass spectrometer
    Ge, X
    Sirich, TL
    Beyer, MK
    Desaire, H
    Leary, JA
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (21) : 5078 - 5082
  • [9] Kolakowski BM, 2000, RAPID COMMUN MASS SP, V14, P772, DOI 10.1002/(SICI)1097-0231(20000515)14:9<772::AID-RCM942>3.0.CO
  • [10] 2-K