Inter- and intraobserver variability of CT measurements obtained after endovascular repair of abdominal aortic aneurysms

被引:79
作者
Wever, JJ
Blankensteijn, JD
van Rijn, JC
Broeders, IAMJ
Eikelboom, BC
Mali, WPTM
机构
[1] Univ Utrecht, Med Ctr, Dept Vasc Surg, NL-3584 CX Utrecht, Netherlands
[2] Univ Utrecht, Med Ctr, Dept Radiol, NL-3584 CX Utrecht, Netherlands
关键词
D O I
10.2214/ajr.175.5.1751279
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. important decisions are made on the basis of CT angiographic measurements of aneurysm size obtained after endovascular abdominal aortic aneurysm repair; however, little is known about the variability of these measurements. We evaluated the variability of CT angiographic measurements of aneurysm size obtained after endovascular abdominal aortic aneurysm repair. MATERIALS AND METHODS. Thirty CT angiographic data sets were randomly chosen from 91 sets, including preoperative, postoperative, and follow-up CT images. All images were obtained according to a standardized acquisition protocol. On a workstation, three parameters were measured: maximum aneurysm diameter, maximum aneurysm cross-sectional area, and aneurysm volume. All data sets were measured twice by two investigators in a random order. The difference of each pair of measurements was plotted against the mean value. The mean difference and its standard deviation were calculated with a repeatability coefficient. RESULTS. The intraobserver repeatability coefficient for observer 1 was 3.8 mm for diameter, 201.7 mm(2) for cross-sectional area, and 5.6 mt for volume. For observer 2, these figures were 3.0 mm, 219.0 mm(2), and S.1 mt, respectively. The interobserver repeatability coefficients were 3.9 mm, 236.2 mm(2), and 10.3 mt. CONCLUSION. Determination of the repeatability coefficient of aneurysm size measurements obtained after endovascular abdominal aortic aneurysm repair provides a good description of precision.
引用
收藏
页码:1279 / 1282
页数:4
相关论文
共 10 条
[1]   CT-angiography of abdominal aortic aneurysms after transfemoral endovascular aneurysm management [J].
Balm, R ;
Kaatee, R ;
Blankensteijn, JD ;
Mali, WPTM ;
Eikelboom, BC .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1996, 12 (02) :182-188
[2]  
BALM R, 1996, TRANSFEMORAL ENDOVAS, P43
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   The efficacy of transfemoral endovascular aneurysm management: A study on size changes of the abdominal aorta during mid-term follow-up [J].
Broeders, IAMJ ;
Blankensteijn, JD ;
Gvakharia, A ;
May, J ;
Bell, PRF ;
Swedenborg, J ;
Collin, J ;
Eikelboom, BC .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1997, 14 (02) :84-90
[5]   Options for treatment of persistent aneurysm perfusion after endovascular repair [J].
Ivancev, K ;
Chuter, T ;
Lindh, M ;
Lindbladt, B ;
Brunkwall, J ;
Risberg, B .
WORLD JOURNAL OF SURGERY, 1996, 20 (06) :673-678
[6]  
Malina M, 1997, J ENDOVASC SURG, V4, P23, DOI 10.1583/1074-6218(1997)004<0023:CAMAEG>2.0.CO
[7]  
2
[8]   Clinical consequences of periprosthetic leak after endovascular repair of abdominal aortic aneurysm [J].
Matsumura, JS ;
Moore, WS .
JOURNAL OF VASCULAR SURGERY, 1998, 27 (04) :606-613
[9]   Conversion from endoluminal to open repair of abdominal aortic aneurysms: A hazardous procedure [J].
May, J ;
White, GH ;
Yu, W ;
Waugh, R ;
Stephen, M ;
Sieunarine, K .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1997, 14 (01) :4-11
[10]   Persistent collateral perfusion of abdominal aortic aneurysm after endovascular repair does not lead to progressive change in aneurysm diameter [J].
Resch, T ;
Ivancev, K ;
Lindh, M ;
Nyman, U ;
Brunkwall, J ;
Malina, M ;
Lindblad, B .
JOURNAL OF VASCULAR SURGERY, 1998, 28 (02) :242-249