(1→3)-β-D-glucan and endotoxin in house dust and peak flow variability in children

被引:175
作者
Douwes, J
Zuidhof, A
Doekes, G
van der Zee, S
Wouters, I
Boezen, HM
Brunekreef, B
机构
[1] Univ Wageningen & Res Ctr, Environm & Occupat Hlth Grp, NL-6700 AE Wageningen, Netherlands
[2] Univ Groningen, Dept Epidemiol, Groningen, Netherlands
[3] Wellington Sch Med, Wellington Asthma Res Grp, Wellington, New Zealand
关键词
D O I
10.1164/ajrccm.162.4.9909118
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
House dust-associated bacterial endotoxins have been shown to be associated with asthma severity, and a similar role has been suggested for fungal (1-->3)-beta-D-glucans. In this study the relation between these agents and peak expiratory flow (PEF) variability was investigated in 148 children 7 to 11 yr of age of whom 50% had self- or parent-reported chronic respiratory symptoms. All children self-monitored twice daily their PEF for a period of 16 wk. Dust samples were collected from mattresses and from living room and bedroom floors, and endotoxin and (1-->3)-beta-D-glucan were measured in dust extracts. The relations with mean daily PEF variability (Ampl%mean) were investigated by linear regression analysis, adjusting for dust mite allergen levels, presence of pets, and type of floor cover. In unadjusted analyses the levels of both endotoxin and (1-->3)-beta-D-glucan per square meter of living room floor were significantly associated with PEF-variability (but not when expressed per gram of sampled dust), particularly in atopic children with asthma symptoms. Adjusted analyses showed the same association for (1-->3)-beta-D-glucan but not for endotoxin. Although no associations were found with microbial agent levels in bedroom floor or mattress dust, high levels of (1-->3)-beta-D-glucan in living room floor dust apparently increase PEF variability in asthmatic children.
引用
收藏
页码:1348 / 1354
页数:7
相关论文
共 38 条
  • [1] Andriessen JW, 1998, CLIN EXP ALLERGY, V28, P1191, DOI 10.1046/j.1365-2222.1998.00322.x
  • [2] [Anonymous], Lev, V14
  • [3] ASTHMATIC SYMPTOMS AND INDOOR LEVELS OF MICROORGANISMS AND HOUSE-DUST MITES
    BJORNSSON, E
    NORBACK, D
    JANSON, C
    WIDSTROM, J
    PALMGREN, U
    STROM, G
    BOMAN, G
    [J]. CLINICAL AND EXPERIMENTAL ALLERGY, 1995, 25 (05) : 423 - 431
  • [4] BLACKLEY CH, 1873, HAY FEVER EXPT RES C
  • [5] HOME DAMPNESS AND RESPIRATORY MORBIDITY IN CHILDREN
    BRUNEKREEF, B
    DOCKERY, DW
    SPEIZER, FE
    WARE, JH
    SPENGLER, JD
    FERRIS, BG
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1989, 140 (05): : 1363 - 1367
  • [6] INHALED ENDOTOXIN AND DECREASED SPIROMETRIC VALUES - AN EXPOSURE RESPONSE RELATION FOR COTTON DUST
    CASTELLAN, RM
    OLENCHOCK, SA
    KINSLEY, KB
    HANKINSON, JL
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1987, 317 (10) : 605 - 610
  • [7] COLOFF MJ, 1992, CLIN EXP ALLERGY S, V22, P1
  • [8] RESPIRATORY HEALTH-EFFECTS OF HOME DAMPNESS AND MOLDS AMONG CANADIAN CHILDREN
    DALES, RE
    ZWANENBURG, H
    BURNETT, R
    FRANKLIN, CA
    [J]. AMERICAN JOURNAL OF EPIDEMIOLOGY, 1991, 134 (02) : 196 - 203
  • [9] Fungal extracellular polysaccharides in house dust as a marker for exposure to fungi: Relations with culturable fungi, reported home dampness, and respiratory symptoms
    Douwes, J
    van der Sluis, B
    Doekes, G
    van Leusden, F
    Wijnands, L
    van Strien, R
    Verhoeff, A
    Brunekreef, B
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1999, 103 (03) : 494 - 500
  • [10] INFLUENCE OF VARIOUS DUST SAMPLING AND EXTRACTION METHODS ON THE MEASUREMENT OF AIRBORNE ENDOTOXIN
    DOUWES, J
    VERSLOOT, P
    HOLLANDER, A
    HEEDERIK, D
    DOEKES, G
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1995, 61 (05) : 1763 - 1769