Leaf chlorophyll fluorescence corrected for re-absorption by means of absorption and reflectance measurements

被引:215
作者
Gitelson, AA
Buschmann, C
Lichtenthaler, HK
机构
[1] Ben Gurion Univ Negev, Jacob Blaustein Inst Desert Res, Remote Sensing Lab, IL-84990 Sede Boqer, Israel
[2] Ben Gurion Univ Negev, Dept Geog & Environm Sci, IL-84990 Sede Boqer, Israel
[3] Univ Karlsruhe, Inst Bot, D-76128 Karlsruhe, Germany
关键词
corrected or retrieved chlorophyll fluorescence spectrum; Fagus sylvatica; in vivo absorption of leaves; in vivo chlorophyll fluorescence; Parthenocissus tricuspidata; re-absorption of chlorophyll fluorescence; reflectance; Ulmus minor;
D O I
10.1016/S0176-1617(98)80143-0
中图分类号
Q94 [植物学];
学科分类号
071001 ;
摘要
The in vivo emission spectra of chlorophyll (Chl) fluorescence of green leaves, taken at room temperature, show two maxima near 685 nm and 735 nm. The shape of the spectra is modified by re-absorption processes and depends on the Chl content of leaves. By performing reflectance, transmission of fluorescence measurements, we investigated the reason for the repeatedly reported increase of fluorescence ratio F685/F735 during stress or damage-induced breakdown of chlorophyll in plants. The in vivo spectra of Chl fluorescence (F), transmittance (T) and reflectance (R) were taken at room temperature at the same leaf spot. Leaves with a wide range of green colour (Chl content varied from 70 to 670 mg m(2)) were chosen from a beech (Fagus sylvatica L.) and an elm tree (Ulmus minor Miller) as well as from a wild shrub (Parthenocissus tricuspidata L.). Strict linear correlations (with a determination coefficient of r(2) > 0.92) were found between the ratio F685/F735 on the one hand, and (i) the ratio of the non-absorbed radiation (R685 + T685)/(R735 + T735), (ii) the reflectance ratio R685/R735, and (iii) the reflectance at 685 nm, on the other hand. The results demonstrate that 92% or more of the ratio F685/F735 variation in leaves during development or at damage and stress events is determined by the variation in Chl content and corresponding changes of the optical properties of leaves. The Chl fluorescence emission spectrum has been corrected at each wavelength for re-absorption by means of non-absorbed radiation (R + T) and reflectance yielding the actually emitted retrieved Chl fluorescence. The retrieved Chl fluoroescence at 685 and 735 nm is found to linearily increase with the Chl content. The shape of the retrieved Chl fluorescence spectrum was very similar to that of strongly diluted Chl alpha in solution, only the position of the emission maxima is different (673 nm and Chl alpha in ethanol solution, and 685 nm in leaves). Studies on the actually emitted <<true>> Chl fluorescence, as retrieved from room temperature and outdoor fluorescence measurements, may show new ways of plant stress detection.
引用
收藏
页码:283 / 296
页数:14
相关论文
共 44 条
[1]   A SIMPLE APPROACH TO THE EVALUATION OF THE REABSORPTION OF CHLOROPHYLL FLUORESCENCE-SPECTRA IN INTACT LEAVES [J].
AGATI, G ;
FUSI, F ;
MAZZINGHI, P ;
DIPAOLO, ML .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY, 1993, 17 (02) :163-171
[2]  
[Anonymous], 1969, Photosynthesis
[3]  
[Anonymous], 1988, APPL CHLOROPHYLL FLU
[4]   Light-induced and age-dependent development of chloroplasts in etiolated barley leaves as visualized by determination of photosynthetic pigments, CO2 assimilation rates and different kinds of chlorophyll fluorescence ratios [J].
Babani, F ;
Lichtenthaler, HK .
JOURNAL OF PLANT PHYSIOLOGY, 1996, 148 (05) :555-566
[5]   MEASUREMENT OF CHLOROPHYLL FLUORESCENCE WITHIN LEAVES USING A FIBEROPTIC MICROPROBE [J].
BORNMAN, JF ;
VOGELMANN, TC ;
MARTIN, G .
PLANT CELL AND ENVIRONMENT, 1991, 14 (07) :719-725
[6]   Application of the Karlsruhe CCD-OMA LIDAR-fluorosensor in stress detection of plants [J].
Buschmann, C ;
Schweiger, J ;
Lichtenthaler, HK ;
Richter, P .
JOURNAL OF PLANT PHYSIOLOGY, 1996, 148 (05) :548-554
[7]  
Buschmann C., 1981, PHOTOSYNTHESIS, VV, P417
[8]  
BUSCHMANN C, 1988, APPLICATIONS CHLOROP, P77
[9]  
Butler WL, 1977, ENCYCLOPEDIA PLANT P, V5, P149
[10]  
Dahn H.G., 1992, EARSEL ADV REMOTE SE, V1, P12