The MG Composite A valid and reliable outcome measure for myasthenia gravis

被引:186
作者
Burns, Ted M. [1 ]
Conaway, Mark [1 ]
Sanders, Donald B. [1 ]
机构
[1] Univ Virginia, Dept Neurol, Charlottesville, VA 22908 USA
关键词
QUALITY-OF-LIFE; MYCOPHENOLATE-MOFETIL; STANDARDS; TRIAL; AZATHIOPRINE; RELIABILITY; INSTRUMENT; SCORE;
D O I
10.1212/WNL.0b013e3181dc1b1e
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To study the concurrent and construct validity and test-retest reliability in the practice setting of an outcome measure for myasthenia gravis (MG). Methods: Eleven centers participated in the validation study of the Myasthenia Gravis Composite (MGC) scale. Patients with MG were evaluated at 2 consecutive visits. Concurrent and construct validities of the MGC were assessed by evaluating MGC scores in the context of other MG-specific outcome measures. We used numerous potential indicators of clinical improvement to assess the sensitivity and specificity of the MGC for detecting clinical improvement. Test-retest reliability was performed on patients at the University of Virginia. Results: A total of 175 patients with MG were enrolled at 11 sites from July 1, 2008, to January 31, 2009. A total of 151 patients were seen in follow-up. Total MGC scores showed excellent concurrent validity with other MG-specific scales. Analyses of sensitivities and specificities of the MGC revealed that a 3-point improvement in total MGC score was optimal for signifying clinical improvement. A 3-point improvement in the MGC also appears to represent a meaningful improvement to most patients, as indicated by improved 15-item myasthenia gravis quality of life scale (MG-QOL15) scores. The psychometric properties were no better for an individualized subscore made up of the 2 functional domains that the patient identified as most important to treat. The test-retest reliability coefficient of the MGC was 98%, with a lower 95% confidence interval of 97%, indicating excellent test-retest reliability. Conclusions: The Myasthenia Gravis Composite is a reliable and valid instrument for measuring clinical status of patients with myasthenia gravis in the practice setting and in clinical trials. Neurology (R) 2010;74:1434-1440
引用
收藏
页码:1434 / 1440
页数:7
相关论文
共 24 条
[1]   Standards of measurements in myasthenia gravis [J].
Barohn, RJ .
MYASTHENIA GRAVIS AND RELATED DISORDERS: BIOCHEMICAL BASIS FOR DISEASE OF THE NEUROMUSCULAR JUNCTION, 2003, 998 :432-439
[2]   Reliability testing of the quantitative myasthenia gravis score [J].
Barohn, RJ ;
McIntire, D ;
Herbelin, L ;
Wolfe, GI ;
Nations, S ;
Bryan, WW .
MYASTHENIA GRAVIS AND RELATED DISEASES: DISORDERS OF THE NEUROMUSCULAR JUNCTION, 1998, 841 :769-772
[3]   Less is more, or almost as much: A 15-item quality-of-life instrument for myasthenia gravis [J].
Burns, Ted M. ;
Conaway, Mark R. ;
Cutter, Gary R. ;
Sanders, Donald B. .
MUSCLE & NERVE, 2008, 38 (02) :957-963
[4]   CONSTRUCTION OF AN EFFICIENT EVALUATIVE INSTRUMENT FOR MYASTHENIA GRAVIS: THE MG COMPOSITE [J].
Burns, Ted M. ;
Conaway, Mark R. ;
Cutter, Gary R. ;
Sanders, Donald B. .
MUSCLE & NERVE, 2008, 38 (06) :1553-1562
[5]   FUNCTIONAL ACTIVITIES OF AUTOANTIBODIES TO ACETYLCHOLINE-RECEPTORS AND THE CLINICAL SEVERITY OF MYASTHENIA-GRAVIS [J].
DRACHMAN, DB ;
ADAMS, RN ;
JOSIFEK, LF ;
SELF, SG .
NEW ENGLAND JOURNAL OF MEDICINE, 1982, 307 (13) :769-775
[6]   MRI and clinical studies of facial and bulbar muscle involvement in MUSK antibody-associated myasthenia gravis [J].
Farrugia, Maria Elena ;
Robson, Matthew D. ;
Clover, Linda ;
Anslow, Phil ;
Newsom-Davis, John ;
Kennett, Robin ;
Hilton-Jones, David ;
Matthews, Paul M. ;
Vincent, Angela .
BRAIN, 2006, 129 :1481-1492
[7]  
Fleis J.L., 1986, DESIGN ANAL CLIN EXP
[8]   Standards of measurements in myasthenia gravis [J].
Gajdos, P ;
Sharshar, T ;
Chevret, S .
MYASTHENIA GRAVIS AND RELATED DISORDERS: BIOMCHEMICAL BASIS FOR DISEASE OF THE NEUROMUSCULAR JUNCTION, 2003, 998 :445-452
[9]   Lifetime course of myasthenia gravis [J].
Grob, David ;
Brunner, Norman ;
Namba, Tatsuji ;
Pagala, Murali .
MUSCLE & NERVE, 2008, 37 (02) :141-149
[10]   Myasthenia gravis - Recommendations for clinical research standards [J].
Jaretzki, A ;
Barohn, RJ ;
Ernstoff, RM ;
Kaminski, HJ ;
Keesey, JC ;
Penn, AS ;
Sanders, DB .
NEUROLOGY, 2000, 55 (01) :16-23